null
close
close
click to zoom in
  • Guaranteed Fitment

    Always the correct part

  • In-House Experts

    We know our products

  • Added Value

    Fast & Reliable

  • US & Canada Delivery

Megger DET4TCR2 4-Terminal Digital Ground Resistance Tester with rechargeable battery

No reviews yet Write a Review
$3,264.61
SKU:
DET4TCR2
Condition:
New
Availability:
In Stock
5 customers are viewing this product

Megger DET4TCR2 4-Terminal Digital Ground Resistance Tester with rechargeable battery

$3,264.61

Megger DET4TCR2

Designed to negate the need for a shorting link when making two-pole measurements, this ground tester also labeled auxiliary controls used to select the test frequency (94, 105, 111, and 128 Hz), output voltage (50 or 25 V where local standards apply), and to switch the backlight on or off.

Features

  • Stakeless testing capability - Allows the operator to use the instrument like a clamp-on tester in applications where the method is viable
  • Attached Rod Technique capability - Allows fall of potential testing without the need to disconnect the ground rod
  • Multiple user selectable test frequencies allows the operator to find the most effective frequency for making the measurement
  • 200,000 ? measurement range provides the ability to measure the resistivity of any type of soil
  • User selectable test voltage ensures that the units can be used in agricultural environments
  • Microprocessor control for improved error detection
  • Clear, unambiguous warnings and error indications ensure the reliability of the reading and reduce test time
  • Rugged, weatherproof case to IP54
  • Backlit LCD allows for testing in dark environments
  • Noise rejection to 40 V pk to pk allows accurate testing in noisy environments
  • Accuracy of 2% of reading enhances reliability of measurements
  • Voltmeter function allows you to measure the ground voltage and enhances operator safety
  • CAT IV 100V provides increased operator safety

Applications

  • Primary and secondary electrical grounding systems
  • Utility pole grounds
  • Lightning protection systems
  • Residential grounds
  • Machinery safety grounds
  • Computer and communication system grounds
  • EMI/RFI system grounds
  • Antenna and pedestal grounds
  • CATV system grounds

Megger DET4TCR2 Specifications

Resistance Range 0.01 ? to 200 k?
Resistance Accuracy 2p Measurements: 2% ±3 digits
3p Measurements: 2% ±3 digits
4p Measurements: 2% ±3 digits
ART Measurements: 5% ±3 digits
Stakeless Measurements: 7% ±3 digits
Maximum Probe Resistance Rp limit: 200 k? (50 V output voltage)
Rc limit: 200 k? (50 V output voltage)
Limits reduced to 100 k? for 25 V output voltage
Limits reduced to 5 k? for 0.01 ? resolution
Earth Voltage Range: 0 to 100 V AC
Accuracy: 2% ±2 V
C Spike Check Automatic
P Spike Check Automatic
Noise Check: Automatic
Rejection: 40 V pk to pk
Test Frequency: 94, 105, 111 and 128 Hz
Voltage: 25 or 50 V, user selectable (factory setting 50 V)
Current: 450 micro-amps at 25 or 50 V (selectable), 4.5 mA at 25 V
Display 3½" digit high contrast LCD, backlit
Battery Type: 8 x 1.5 V AA NiMH rechargeable cells
Life: 3 hours, 700 consecutive tests
Temperature Range Operating: 5 to 131°F (-15 to 55°C)
Storage: -40 to 158°F (-40 to 70°C)
Humidity 95% RH non-condensing at 104°F (40°C)
Safety EN61010-1 CAT IV 100 V
Ingress Protection IP54
Dimensions 8 x 5.7 x 3.2" (203 x 148 x 78 mm)
Weight 2.20 lbs (1 kg)

Megger DET4TCR2 Specifications

Resistance Range 0.01 ? to 200 k?
Resistance Accuracy 2p Measurements: 2% ±3 digits
3p Measurements: 2% ±3 digits
4p Measurements: 2% ±3 digits
ART Measurements: 5% ±3 digits
Stakeless Measurements: 7% ±3 digits
Maximum Probe Resistance Rp limit: 200 k? (50 V output voltage)
Rc limit: 200 k? (50 V output voltage)
Limits reduced to 100 k? for 25 V output voltage
Limits reduced to 5 k? for 0.01 ? resolution
Earth Voltage Range: 0 to 100 V AC
Accuracy: 2% ±2 V
C Spike Check Automatic
P Spike Check Automatic
Noise Check: Automatic
Rejection: 40 V pk to pk
Test Frequency: 94, 105, 111 and 128 Hz
Voltage: 25 or 50 V, user selectable (factory setting 50 V)
Current: 450 micro-amps at 25 or 50 V (selectable), 4.5 mA at 25 V
Display 3½" digit high contrast LCD, backlit
Battery Type: 8 x 1.5 V AA NiMH rechargeable cells
Life: 3 hours, 700 consecutive tests
Temperature Range Operating: 5 to 131°F (-15 to 55°C)
Storage: -40 to 158°F (-40 to 70°C)
Humidity 95% RH non-condensing at 104°F (40°C)
Safety EN61010-1 CAT IV 100 V
Ingress Protection IP54
Dimensions 8 x 5.7 x 3.2" (203 x 148 x 78 mm)
Weight 2.20 lbs (1 kg)

Megger DET4TCR2 Specifications

Resistance Range 0.01 ? to 200 k?
Resistance Accuracy 2p Measurements: 2% ±3 digits
3p Measurements: 2% ±3 digits
4p Measurements: 2% ±3 digits
ART Measurements: 5% ±3 digits
Stakeless Measurements: 7% ±3 digits
Maximum Probe Resistance Rp limit: 200 k? (50 V output voltage)
Rc limit: 200 k? (50 V output voltage)
Limits reduced to 100 k? for 25 V output voltage
Limits reduced to 5 k? for 0.01 ? resolution
Earth Voltage Range: 0 to 100 V AC
Accuracy: 2% ±2 V
C Spike Check Automatic
P Spike Check Automatic
Noise Check: Automatic
Rejection: 40 V pk to pk
Test Frequency: 94, 105, 111 and 128 Hz
Voltage: 25 or 50 V, user selectable (factory setting 50 V)
Current: 450 micro-amps at 25 or 50 V (selectable), 4.5 mA at 25 V
Display 3½" digit high contrast LCD, backlit
Battery Type: 8 x 1.5 V AA NiMH rechargeable cells
Life: 3 hours, 700 consecutive tests
Temperature Range Operating: 5 to 131°F (-15 to 55°C)
Storage: -40 to 158°F (-40 to 70°C)
Humidity 95% RH non-condensing at 104°F (40°C)
Safety EN61010-1 CAT IV 100 V
Ingress Protection IP54
Dimensions 8 x 5.7 x 3.2" (203 x 148 x 78 mm)
Weight 2.20 lbs (1 kg)
Shipping & Return
Returns Policy

All returns must be authorized. Items returned prior to authorization will not be accepted. For international customers where applicable, customers must ship any returns to us freight and duty prepaid. Return freight charges for internationsl shippments will be the responsibility of the customer.

Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.

Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.

(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)

Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.

Shipping

We can ship to both US and Canada. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

When you place an order, we will charge a flat rate shipping for your items.

Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.

Not Applicable

Condition: NA

Frequently Asked Questions

  • How do I request a quote?
    To request a quote for pricing on any item found on our site, please click on our "REQUEST A QUOTE" link. Fill out and submit the form, one of our representatives will contact you when the quote is ready.
  • What payment options do I have?
    EquipTestPro accepts a variety of payment options for your convenience. For prepayment, we accept all major credit cards (MasterCard, Visa, Amex, Discover), Purchase Orders, and wire transfers.
  • How do I retturn items?
    All returns must be authorized. Items returned prior to authorization will not be accepted. For international customers where applicable, customers must ship any returns to us freight and duty prepaid. Return freight charges for internationsl shippments will be the responsibility of the customer.

    Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.

    Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.

    (Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)

    Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.

Canada & US Shipping
Rewards Program
Secure Shopping
30-Day Free Returns