Megger DET4TD2 4-Terminal Digital Ground Tester, 2, 3 and 4 point testing

$2,412.45

Megger DET4TD2

Dry-cell battery powered and highly reliable, this ground tester automatically checks the connection and conditions of the P spike, C spike, and the level of ground noise, indicating the status on the display. The tester also a voltmeter to enable the measurement of ground voltage.

Features

  • 2, 3 and 4 point testing
  • Multiple, user selectable test frequencies
  • Warning indicators prevent test failure
  • Simple one button operation
  • Multiple, user selectable test frequencies allows the operator to find the most effective frequency for making the measurement
  • 200,000 ? measurement range provides the ability to measure the resistivity of any type of soil
  • User selectable test voltage ensures that the units can be used in agricultural environments
  • Microprocessor control for improved error detection
  • Clear, unambiguous warnings and error indications ensure the reliability of the reading and reduce test time
  • Accuracy of 2% of reading enhances reliability of measurements
  • CAT IV 100V provides increased operator safety

Applications

  • Primary and secondary electrical grounding systems
  • Utility pole grounds§Lightning protection systems
  • Residential grounds§Machinery safety grounds
  • Computer and communication system grounds
  • EMI/RFI system grounds
  • Antenna and pedestal grounds
  • CATV system grounds

Megger DET4TD2 Specifications

Resistance Range 0.01 to 20 k?
Resistance Accuracy 2P measurements: 2% ±3 digits
3P measurements: 2% ±3 digits
4P measurements: 2% ±3 digits
Maximum Probe Resistance Rp limit: 100 k? (50 V output voltage)
Rc limit: 100k? (50V output voltage)
Limits reduced to 50 k? for 25 V output voltage
Limits reduced to 5k? for 0.01 ? resolution
Earth Voltage Range: 0 to 100 V
Accuracy: 2% ±2 V
Wire Tests 2: Yes
3: Yes
4: Yes
Ground Current Range (with Current Measuring Clamp) 0.5 mA to 19.9 A
Ground Current Accuracy 5% ±3 digits
Test Frequency Frequency: 128 Hz
Voltage: 25 V or 50 V, user selectable (factory setting 50 V)
Current: 450 µA at 25 V or 50 V (selectable), 4.5 mA at 25 V
Noise Rejection: 40 V peak to peak
Check: Automatic
Spike Check C: Automatic
P: Automatic
General Specifications
Battery 8 x 1.5 V AA cell
Battery Life 3 hours, 700 consecutive tests
Display 3 ½ digit high contrast LCD
Safety EN61010-1 CAT IV 100 V
Terminals 4 mm plug type (test leads)
Temperature Operating: 5 to 131°F (-15 to 55°C)
Storage: -40 to 158°F (-40 to +70°C)
Humidity: 95% RH non-condensing at 104°F (40°C)
Ingress Protection IP54
EMC Meets the requirements of EN61326-1:1998 for use in heavy industrial areas, including amendment 1
Dimensions 8 x 5.7 x 3.2" (203 x 148 x 78 mm)
Weight 2.2 lbs (1 kg)

Megger DET4TD2 Specifications

Resistance Range 0.01 to 20 k?
Resistance Accuracy 2P measurements: 2% ±3 digits
3P measurements: 2% ±3 digits
4P measurements: 2% ±3 digits
Maximum Probe Resistance Rp limit: 100 k? (50 V output voltage)
Rc limit: 100k? (50V output voltage)
Limits reduced to 50 k? for 25 V output voltage
Limits reduced to 5k? for 0.01 ? resolution
Earth Voltage Range: 0 to 100 V
Accuracy: 2% ±2 V
Wire Tests 2: Yes
3: Yes
4: Yes
Ground Current Range (with Current Measuring Clamp) 0.5 mA to 19.9 A
Ground Current Accuracy 5% ±3 digits
Test Frequency Frequency: 128 Hz
Voltage: 25 V or 50 V, user selectable (factory setting 50 V)
Current: 450 µA at 25 V or 50 V (selectable), 4.5 mA at 25 V
Noise Rejection: 40 V peak to peak
Check: Automatic
Spike Check C: Automatic
P: Automatic
General Specifications
Battery 8 x 1.5 V AA cell
Battery Life 3 hours, 700 consecutive tests
Display 3 ½ digit high contrast LCD
Safety EN61010-1 CAT IV 100 V
Terminals 4 mm plug type (test leads)
Temperature Operating: 5 to 131°F (-15 to 55°C)
Storage: -40 to 158°F (-40 to +70°C)
Humidity: 95% RH non-condensing at 104°F (40°C)
Ingress Protection IP54
EMC Meets the requirements of EN61326-1:1998 for use in heavy industrial areas, including amendment 1
Dimensions 8 x 5.7 x 3.2" (203 x 148 x 78 mm)
Weight 2.2 lbs (1 kg)

Megger DET4TD2 Specifications

Resistance Range 0.01 to 20 k?
Resistance Accuracy 2P measurements: 2% ±3 digits
3P measurements: 2% ±3 digits
4P measurements: 2% ±3 digits
Maximum Probe Resistance Rp limit: 100 k? (50 V output voltage)
Rc limit: 100k? (50V output voltage)
Limits reduced to 50 k? for 25 V output voltage
Limits reduced to 5k? for 0.01 ? resolution
Earth Voltage Range: 0 to 100 V
Accuracy: 2% ±2 V
Wire Tests 2: Yes
3: Yes
4: Yes
Ground Current Range (with Current Measuring Clamp) 0.5 mA to 19.9 A
Ground Current Accuracy 5% ±3 digits
Test Frequency Frequency: 128 Hz
Voltage: 25 V or 50 V, user selectable (factory setting 50 V)
Current: 450 µA at 25 V or 50 V (selectable), 4.5 mA at 25 V
Noise Rejection: 40 V peak to peak
Check: Automatic
Spike Check C: Automatic
P: Automatic
General Specifications
Battery 8 x 1.5 V AA cell
Battery Life 3 hours, 700 consecutive tests
Display 3 ½ digit high contrast LCD
Safety EN61010-1 CAT IV 100 V
Terminals 4 mm plug type (test leads)
Temperature Operating: 5 to 131°F (-15 to 55°C)
Storage: -40 to 158°F (-40 to +70°C)
Humidity: 95% RH non-condensing at 104°F (40°C)
Ingress Protection IP54
EMC Meets the requirements of EN61326-1:1998 for use in heavy industrial areas, including amendment 1
Dimensions 8 x 5.7 x 3.2" (203 x 148 x 78 mm)
Weight 2.2 lbs (1 kg)
Shipping & Return
Returns Policy

All returns must be authorized. Items returned prior to authorization will not be accepted. For international customers where applicable, customers must ship any returns to us freight and duty prepaid. Return freight charges for internationsl shippments will be the responsibility of the customer.

Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.

Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.

(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)

Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.

Shipping

We can ship to both US and Canada. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

When you place an order, we will charge a flat rate shipping for your items.

Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.

Not Applicable

Condition: NA

Frequently Asked Questions

  • How do I request a quote?
    To request a quote for pricing on any item found on our site, please click on our "REQUEST A QUOTE" link. Fill out and submit the form, one of our representatives will contact you when the quote is ready.
  • What payment options do I have?
    EquipTestPro accepts a variety of payment options for your convenience. For prepayment, we accept all major credit cards (MasterCard, Visa, Amex, Discover), Purchase Orders, and wire transfers.
  • How do I retturn items?
    All returns must be authorized. Items returned prior to authorization will not be accepted. For international customers where applicable, customers must ship any returns to us freight and duty prepaid. Return freight charges for internationsl shippments will be the responsibility of the customer.

    Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.

    Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.

    (Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)

    Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.

Canada & US Shipping
Rewards Program
Secure Shopping
30-Day Free Returns