Megger MCT105 Cable Locator Kit, 12 to 400 V, 0 to 60 Hz
SKU: 1013-836
Availability: 2 to 3 Weeks Megger MCT105 Offers Locate and identify fuses or breakers on electrical circuits with this cable locator kit that finds breaks or short circuits in cables and electrical underfloor heating systems. Detect cables buried up to an 8.2′ (2.5 m) depth with the receiver that offers automatic or manual adjustment of signal sensitivity for increase accuracy. In addition, the transmitter generates a signal on dead or isolate
Availability: 2 to 3 Weeks
Megger MCT105 Offers
Locate and identify fuses or breakers on electrical circuits with this cable locator kit that finds breaks or short circuits in cables and electrical underfloor heating systems. Detect cables buried up to an 8.2' (2.5 m) depth with the receiver that offers automatic or manual adjustment of signal sensitivity for increase accuracy. In addition, the transmitter generates a signal on dead or isolated cables and conductors, and this kit allows you to trace metal water and heating pipes.
Features
- Trace cables and conductors in walls
- Works on both live and dead cables or conductors
- Locate conductor breaks and short circuits
- Identify fuses and circuit breakers
- Trace conductors buried in the ground
- Trace metal water and heating pipes
- Visual and audible signal strength indication
- Non-contact voltage detector (Receiver)
- Automatic or manual sensitivity adjustment
- Built in torch (Receiver)
- Identify cable and conductor interruptions (open-circuits) or short-circuit faults
- Cable and conductor tracing in the soil
- Identify fuses and circuit breakers within distribution boards
- Detecting interruptions and short-circuits in floor heating
- Tracing metallic water and heating piping
- Transmitter display indicates signal level, the transmission code, as well as any voltage detected on the output terminals
- Receiver display indicates the signal strength, the transmission code, as well as the presence of mains voltage
- Automatic and manual sensitivity adjustment
- Variable tone audible signal level on the receiver (may be switched off)
- Auto-Power-Off function
- Backlight on both transmitter and receiver displays
- Torch function when working under bad lighting conditions
Applications
- Detects and traces cables or metallic conductors in walls or buried underground , locate and identify fuses or breakers on electrical circuits as well as finding breaks or short circuits in cables and electrical underfloor heating systems
- Trace and aid fault location in cables, circuits or metallic conductors, such as pipes
Megger MCT105 Specifications
| Transmitter | |
| Output Signal | 125 kHz |
| Ranges | Voltage: 13 to 400 V Frequency: 0 to 60 Hz |
| Display | LCD display |
| External Voltage Detection | 400 V AC/DC (maximum) |
| Over Voltage Category | CAT Ill 300 V |
| Fuse | F0.5 A 500 V, 6.3 x 32 mm |
| Consumption | Maximum 18 mA |
| Altitude | Up to 6561.68' (2000 m) |
| Temperature | Operating: 32 to 104°F (0 to 40°C), maximum 80% relative humidity (not condensing) Storage: -4 to 140°F (-20 to 60°C), maximum 80% relative humidity (not condensing) |
| Power Supply | One 9 V battery, NEDA 1604, IE6F22.Power |
| Auto Power Off | Approximately 1 hour (after last operation) |
| Pollution Degree | 2 |
| Safety Standard | IEC EN61010-1 CAT III 300 V |
| Dimensions | 5.12 x 2.72 x 1.26" (130 x 69 x 32 mm) |
| Weight | Approximately 0.29 lbs (130 g) |
| Receiver | |
| Tracing Depth | The tracing depth depends of medium and application |
| Cable Locator Mode | Approximately 0 to 2 m (single-pole application) Approximately 0 to 0.5 m (double-pole application) |
| Voltage Detection | Approximately 0 to 0.4 m |
| Display | LCD with functions- and bar graph |
| Consumption | Approximately 23 mA (without backlight or lamp) Approximately 35 mA (with backlight) Maximum 40 mA (backlight and lamp) |
| Altitude | Up to 6561.68' (2000 m) |
| Temperature | Operating: 32 to 104°F (0 to 40°C), maximum 80% relative humidity (not condensing) Storage: 68 to 140°F (20 to 60°C), maximum 80% relative humidity (not condensing) |
| Power Supply | One 9 V battery, NEDA 1604, IE6F22.Power |
| Auto Power Off | Approximately 5 minute (no any operation) |
| Safety Standard | IEC EN61010-1 CAT III 300 V |
| Dimensions | 7.56 x 2.4 x 1.46" (192 x 61 x 37 mm) |
| Weight | Approximately 0.4 lbs (180 g) |