null
close
close
click to zoom in
  • Guaranteed Fitment

    Always the correct part

  • In-House Experts

    We know our products

  • Added Value

    Fast & Reliable

  • US & Canada Delivery

Megger MET1000 True RMS Electrical Tester, 200 A, 1000 V

No reviews yet Write a Review
$553.81
SKU:
MET1000
Condition:
New
Availability:
In Stock
5 customers are viewing this product

Megger MET1000 True RMS Electrical Tester, 200 A, 1000 V

$553.81

Megger MET1000

Robust and versatile, this electrical tester features detachable test leads and a built-in current clamp for current measurement to 200 A. Ideal for usage in commercial, industrial, and domestic environments, the electrical tester provides auto-ranging voltage, continuity, true RMS AC measurements, phase rotation tests, and comes complete with both inrush current and single-pole voltage tests.

Features

  • LED and LCD display with self-test
  • Detachable test probes
  • AC/DC voltage to 1000 V
  • Continuity to 50 K?
  • Measures voltage without batteries
  • 200 A AC measurement
  • True RMS on ACV/ACA
  • Inrush current
  • Phase rotation
  • Single pole test
  • Data hold
  • Auto power On/Off
  • 9999 count digital display
  • <0.5 s bar response time
  • <0.5 s DCV reading response time
  • White LED auto backlight display
  • Input peak current <3.5 mA at 1000 V
  • 1.5" (39 mm) width jaw size
  • Up to 0.6" (16 mm) diameter conductor
  • Auto polarity detection
  • ELV Indication
  • Hand guard and streamline design
  • Ø 2 mm/4 mm tips interchangeable
  • LED Torch

Multiple tests

In addition to the versatile auto-ranging voltage and continuity tests, the tester has a built-in current clamp for AC current measurement to 200 A. With TRMS AC measurements, a phase rotation test and both inrush current and single pole voltage test built in, the tester is a truly versatile electrical tester, ideal for use in commercial, industrial and domestic environments. GS38 shrouds are provided as standard to ensure compliance with the latest standards.

A bright LED torch aids safe working in poorly lit conditions and with the added benefit of an IP65 casing - incorporating a protective finger guard - ergonomic design, instrument carrying holster and a simple to use probe mounting on the rear of tester all help to keep the user safe and the instrument protected. Incorporating a comprehensive self-test feature, acoustic continuity and voltage indication, a maximum current draw of >3.5 mA to avoid unwanted tripping of RCD's/RCBO's and the ability to warn the operator of dangerous voltages, even when the batteries are exhausted, ensure the electrical tester meets the practical demands of today's busy test technicians.

Applications

  • Electrical engineering
  • Commercial, industrial, domestic electrical testing

Megger MET1000 Specifications

Sampling Rate 3 times/sec
ACA Range: 200 A
Resolution: 0.1 A
Basic accuracy: ±(3.0% +5 d) at 45 to ~65 Hz
ACV Range with batteries: 6 to ~999.9 V
Range without batteries: 45 to ~999.9 V
Resolution 0.1 V
Basic accuracy: ±(1.5% +5 d) at 45 to ~400 Hz
DCV Range with batteries: 7 to ~999.9 V
Range without batteries: 35 to ~999.9 V
Resolution: 0.1 V
Basic accuracy: ±(1.0% +2 d)
Ohm Range: 50 k?
Basic accuracy: ±(1.5% +5 d)
Resolution: 1 ?
Continuity Beep <1.8 k?, 2.7 kHz tone buzzer
Rotary Field Indication Sensitivity: 90 to 1000 V (phase to earth)
Frequency Range 45 to 65 Hz
Single-Pole Phase Check Sensitivity: 90 to 1000 V (45 to 65 Hz phase to earth)
Response Time Bar: <0.5 s
Reading: <0.5 s
Auto Power Off 30 seconds
Indicator 2.7 kHz tone buzzer and ELV LED
Temperature Operating: 5 to ~131°F (-15°C to ~55°C), ?80% RH
Storage: -4 to ~140°F (-20°C to ~60°C)
Coefficient: 0.2 x (Spec. Acc)/°C, <18°C or >28°C
Jaw Size 1.5" (39 mm)
Maximum Conductor Size 0.6" (16 mm)
Dimensions 2.2 x 8.6 x 1.3" (57 x 220 x 35 mm)
Weight 0.4 lbs (200 g)

Megger MET1000 Specifications

Sampling Rate 3 times/sec
ACA Range: 200 A
Resolution: 0.1 A
Basic accuracy: ±(3.0% +5 d) at 45 to ~65 Hz
ACV Range with batteries: 6 to ~999.9 V
Range without batteries: 45 to ~999.9 V
Resolution 0.1 V
Basic accuracy: ±(1.5% +5 d) at 45 to ~400 Hz
DCV Range with batteries: 7 to ~999.9 V
Range without batteries: 35 to ~999.9 V
Resolution: 0.1 V
Basic accuracy: ±(1.0% +2 d)
Ohm Range: 50 k?
Basic accuracy: ±(1.5% +5 d)
Resolution: 1 ?
Continuity Beep <1.8 k?, 2.7 kHz tone buzzer
Rotary Field Indication Sensitivity: 90 to 1000 V (phase to earth)
Frequency Range 45 to 65 Hz
Single-Pole Phase Check Sensitivity: 90 to 1000 V (45 to 65 Hz phase to earth)
Response Time Bar: <0.5 s
Reading: <0.5 s
Auto Power Off 30 seconds
Indicator 2.7 kHz tone buzzer and ELV LED
Temperature Operating: 5 to ~131°F (-15°C to ~55°C), ?80% RH
Storage: -4 to ~140°F (-20°C to ~60°C)
Coefficient: 0.2 x (Spec. Acc)/°C, <18°C or >28°C
Jaw Size 1.5" (39 mm)
Maximum Conductor Size 0.6" (16 mm)
Dimensions 2.2 x 8.6 x 1.3" (57 x 220 x 35 mm)
Weight 0.4 lbs (200 g)

Megger MET1000 Specifications

Sampling Rate 3 times/sec
ACA Range: 200 A
Resolution: 0.1 A
Basic accuracy: ±(3.0% +5 d) at 45 to ~65 Hz
ACV Range with batteries: 6 to ~999.9 V
Range without batteries: 45 to ~999.9 V
Resolution 0.1 V
Basic accuracy: ±(1.5% +5 d) at 45 to ~400 Hz
DCV Range with batteries: 7 to ~999.9 V
Range without batteries: 35 to ~999.9 V
Resolution: 0.1 V
Basic accuracy: ±(1.0% +2 d)
Ohm Range: 50 k?
Basic accuracy: ±(1.5% +5 d)
Resolution: 1 ?
Continuity Beep <1.8 k?, 2.7 kHz tone buzzer
Rotary Field Indication Sensitivity: 90 to 1000 V (phase to earth)
Frequency Range 45 to 65 Hz
Single-Pole Phase Check Sensitivity: 90 to 1000 V (45 to 65 Hz phase to earth)
Response Time Bar: <0.5 s
Reading: <0.5 s
Auto Power Off 30 seconds
Indicator 2.7 kHz tone buzzer and ELV LED
Temperature Operating: 5 to ~131°F (-15°C to ~55°C), ?80% RH
Storage: -4 to ~140°F (-20°C to ~60°C)
Coefficient: 0.2 x (Spec. Acc)/°C, <18°C or >28°C
Jaw Size 1.5" (39 mm)
Maximum Conductor Size 0.6" (16 mm)
Dimensions 2.2 x 8.6 x 1.3" (57 x 220 x 35 mm)
Weight 0.4 lbs (200 g)
Shipping & Return
Returns Policy

All returns must be authorized. Items returned prior to authorization will not be accepted. For international customers where applicable, customers must ship any returns to us freight and duty prepaid. Return freight charges for internationsl shippments will be the responsibility of the customer.

Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.

Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.

(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)

Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.

Shipping

We can ship to both US and Canada. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

When you place an order, we will charge a flat rate shipping for your items.

Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.

Not Applicable

Condition: NA

Frequently Asked Questions

  • How do I request a quote?
    To request a quote for pricing on any item found on our site, please click on our "REQUEST A QUOTE" link. Fill out and submit the form, one of our representatives will contact you when the quote is ready.
  • What payment options do I have?
    EquipTestPro accepts a variety of payment options for your convenience. For prepayment, we accept all major credit cards (MasterCard, Visa, Amex, Discover), Purchase Orders, and wire transfers.
  • How do I retturn items?
    All returns must be authorized. Items returned prior to authorization will not be accepted. For international customers where applicable, customers must ship any returns to us freight and duty prepaid. Return freight charges for internationsl shippments will be the responsibility of the customer.

    Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.

    Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.

    (Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)

    Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.

Canada & US Shipping
Rewards Program
Secure Shopping
30-Day Free Returns