Megger MIT415/2 Insulation tester for ESD and signal cable testing

Replacing the BMM2000ESD, the Megger MIT415/2 Insulation Tester gives greater application range and greater functionality with simplified operation.

  • 10 V and 100 V ESD testing
  • 25 V & 50 V signal cable insulation testing
  • 250 V & 500 V Insulation testing up to 50 G? (500 V)
  • Continuity testing at 200 mA or 20 mA from 0.01 ? to 999 k?
  • DC and TRMS AC voltage measurement
  • Large backlit display
  • Combined analogue and dual digital readout
  • Weatherproof to IP54
  • Supplied with AA alkaline

The Megger MIT415 insulation and continuity tester is designed for electrical testing by utilities, industrial, commercial and domestic electricians. The wide range of test voltages makes the MIT415 series ideal for the engineer or technician involved with combined applications of both communications circuits and power circuits such as would be found in elevator service/repair and routine maintenance. The low test voltage insulation ranges also makes the MIT415 ideal for ESD testing.

Key Features

  • CAT IV 600 V rating - provides greater safety when testing at higher voltage levels
  • Adjustable insulation test voltages - provides 250 V to 1000 V or 50 V to 1000 V.
  • Dual digital display readout - allows display of complimentary test information simultaneously (for example: M? plus test voltage or M? plus leakage current)
  • Digital and analog arc display - includes not only the digital readout but also Megger's patented analog arc to replicate the response of a moving coil display
  • Exceptional measurement range from 20 G? to 200 G? - highest insulation test range available on the market, providing a superior range of measurement applications.
  • Choice of 20 mA or 200 mA continuity testing - allows user to select lower continuity range thus increasing battery life considerably
  • Continuity auto-test capability - enables real two-handed operation without the need to press the test button
  • Adjustable continuity limit alarm - allows pass/fail limits to be sent to speed testing
  • Automatically perform PI and DAR tests - user is able to quickly perform two important diagnostic tests. . . Polarization Index (PI) and Dielectric Absorption Ratio (DAR)
  • True RMS voltage measurement - allows accurate voltage measurement on noisy lines
  • Auto ranging voltage measurement - automatically adjusts range from millivolts to 600 V AC or DC, eliminating the need to keep changing ranging
  • Live circuit warning - automatically warns of contact to a live circuit, voltage is displayed and testing is inhibited
  • Auto fuse warning - warns of fuse failure automatically. No need to test the fuse manually.
  • Buzzer select button - enable or disable buzzer as required with resistance also displayed on the screen.
  • Stylish tapered design and center button placement - easy to use with either hand

Specifications (MIT400-EN)

*All quoted accuracies are at +20° C.
Insulation Nominal test voltages 250 V, 500 V, 1000 V
Insulation resistance range 20 G?
Range Full Scale Accuracy 1000 volts ±3% ±2 digits ±0.2% per G? 500 volts ±3% ±2 digits ±0.4% per G? 250 volts ±3% ±2 digits ±0.8% per G?
Analog range 1 G? full scale
Short Circuit Current 2 mA +0% -50%
Terminal voltage -0% +20% ±1 V
Test Current on load 1 mA at min. pass value of insulation specified in BS7671, HD384and IEC364, 2 mA max.
EN61557 Operating range 0.10 M½ to 1.00 G?
Leakage Current 10% ±3 digits
Voltage display 3% ±3 digits ±0.5% of rated voltage
Polarization Index (PI) 10 min/1 minute ratio
Dielectric Absorption Ratio (DAR) 60 sec/30 sec ratio
Notes (1) All ranges measure from 0.00 M½ upwards. (2) Above specifications only apply when high quality silicone leadsare being used.
Continuity
Measurement 0.01 ½ to 99.9 ½ (0 to 100 ½ on analog scale)
Accuracy ±3% ±2 digits (0 to 100 ?)
Open circuit voltage 5 V ±1 V
Test current 200 mA (–0 mA +20 mA) (0.01 ½ to 9.99 ?) 20mA (±1 mA ) (10.0 ½ to 99.9 ?)
Zero offset at probe tips 0.10? typical
Lead resistance zeroing Up to 9.00 ?
Buzzer Variable limit 1?, 2?, 5?,10?, 20?
Resistance
Measurement 0.01 k? to 1000 k? (0 to 1 M? on analog scale)
Accuracy ±3% ±2 digits Open circuit voltage 5 V ±1 V Short circuit current 20 µA ± 5 µA
Voltage range 0 to 600 V d.c. ±2% ±2 digits 10 mV to 600 V TRMS sinusoidal (40 to 400 Hz) ±2% ±2 digits 0 to 1000 V on Analog scale Unspecified input level 0 - 10 mV (40 to 400 Hz) For non-sinusoidal waveforms additional specification apply: ±3% ±2 digits 101 mV to 600 V TRMS and ±8% ±2 digits 10 mV to 100 mV TRMS
Default Voltmeter Operates at >25 V a.c. or d.c. on any range except OFF
Frequency 40 - 450 Hz (40 Hz - 99.9 Hz) ±0.5% ±1 digit (100 Hz to450 Hz)
Result storage
Capacity >1000 test results
Download Bluetooth wireless
Bluetooth Class Class II
Range up to 10 m
Power
Power Supply 5 x 1.5 V cells type IEC LR6 (AA, MN1500, HP7, AM3 R6HP) Alkaline NiMH rechargeable cells may be used. Battery life: 2200 insulation tests with duty cycle of 5 sec ON /55 sec OFF @ 1000 V into 1 M?
Dimensions
Instrument 220 x 92 x 50 mm (8.66 in. x 3.63 in. x 1.97 in.)
Instrument and case 456 x 178 x 89 mm (18 in. x 7 in. x 3.5 in.)
Weight
Instrument only 590 gms (20.73 oz.), 775 gms (27.22 oz.) with boot
Instrument and case 1.75kg (3.86 lb)
Fuse Use only a 500 mA (FF) 1000 V 32 x 6 mm ceramic fuse of highbreaking capacity HBC 50 kA minimum. Glass fuses MUST NOT be fitted.
Safety Protection The instruments meet EN 61010-1 (1995) to 600 V phase to earth, Category IV. Refer to safety warnings supplied.
E.M.C. In accordance with IEC 61326 including amendment No.1
Temperature effects
Temperature coefficient <0.1&Omega per °C up to 1 G&Omega
Environmental
Operating range -10 to +55° C
Operating humidity 90% RH at 40° C max.
Storage temperature range -25 to +70° C
Calibration Temperature +20° C
Maximum altitude 2000 m
Dust and water protection IP54 Protected against dust and splashing water

Key Features

  • CAT IV 600 V rating - provides greater safety when testing at higher voltage levels
  • Adjustable insulation test voltages - provides 250 V to 1000 V or 50 V to 1000 V.
  • Dual digital display readout - allows display of complimentary test information simultaneously (for example: M? plus test voltage or M? plus leakage current)
  • Digital and analog arc display - includes not only the digital readout but also Megger's patented analog arc to replicate the response of a moving coil display
  • Exceptional measurement range from 20 G? to 200 G? - highest insulation test range available on the market, providing a superior range of measurement applications.
  • Choice of 20 mA or 200 mA continuity testing - allows user to select lower continuity range thus increasing battery life considerably
  • Continuity auto-test capability - enables real two-handed operation without the need to press the test button
  • Adjustable continuity limit alarm - allows pass/fail limits to be sent to speed testing
  • Automatically perform PI and DAR tests - user is able to quickly perform two important diagnostic tests. . . Polarization Index (PI) and Dielectric Absorption Ratio (DAR)
  • True RMS voltage measurement - allows accurate voltage measurement on noisy lines
  • Auto ranging voltage measurement - automatically adjusts range from millivolts to 600 V AC or DC, eliminating the need to keep changing ranging
  • Live circuit warning - automatically warns of contact to a live circuit, voltage is displayed and testing is inhibited
  • Auto fuse warning - warns of fuse failure automatically. No need to test the fuse manually.
  • Buzzer select button - enable or disable buzzer as required with resistance also displayed on the screen.
  • Stylish tapered design and center button placement - easy to use with either hand

Specifications (MIT400-EN)

*All quoted accuracies are at +20° C.
Insulation Nominal test voltages 250 V, 500 V, 1000 V
Insulation resistance range 20 G?
Range Full Scale Accuracy 1000 volts ±3% ±2 digits ±0.2% per G? 500 volts ±3% ±2 digits ±0.4% per G? 250 volts ±3% ±2 digits ±0.8% per G?
Analog range 1 G? full scale
Short Circuit Current 2 mA +0% -50%
Terminal voltage -0% +20% ±1 V
Test Current on load 1 mA at min. pass value of insulation specified in BS7671, HD384and IEC364, 2 mA max.
EN61557 Operating range 0.10 M½ to 1.00 G?
Leakage Current 10% ±3 digits
Voltage display 3% ±3 digits ±0.5% of rated voltage
Polarization Index (PI) 10 min/1 minute ratio
Dielectric Absorption Ratio (DAR) 60 sec/30 sec ratio
Notes (1) All ranges measure from 0.00 M½ upwards. (2) Above specifications only apply when high quality silicone leadsare being used.
Continuity
Measurement 0.01 ½ to 99.9 ½ (0 to 100 ½ on analog scale)
Accuracy ±3% ±2 digits (0 to 100 ?)
Open circuit voltage 5 V ±1 V
Test current 200 mA (–0 mA +20 mA) (0.01 ½ to 9.99 ?) 20mA (±1 mA ) (10.0 ½ to 99.9 ?)
Zero offset at probe tips 0.10? typical
Lead resistance zeroing Up to 9.00 ?
Buzzer Variable limit 1?, 2?, 5?,10?, 20?
Resistance
Measurement 0.01 k? to 1000 k? (0 to 1 M? on analog scale)
Accuracy ±3% ±2 digits Open circuit voltage 5 V ±1 V Short circuit current 20 µA ± 5 µA
Voltage range 0 to 600 V d.c. ±2% ±2 digits 10 mV to 600 V TRMS sinusoidal (40 to 400 Hz) ±2% ±2 digits 0 to 1000 V on Analog scale Unspecified input level 0 - 10 mV (40 to 400 Hz) For non-sinusoidal waveforms additional specification apply: ±3% ±2 digits 101 mV to 600 V TRMS and ±8% ±2 digits 10 mV to 100 mV TRMS
Default Voltmeter Operates at >25 V a.c. or d.c. on any range except OFF
Frequency 40 - 450 Hz (40 Hz - 99.9 Hz) ±0.5% ±1 digit (100 Hz to450 Hz)
Result storage
Capacity >1000 test results
Download Bluetooth wireless
Bluetooth Class Class II
Range up to 10 m
Power
Power Supply 5 x 1.5 V cells type IEC LR6 (AA, MN1500, HP7, AM3 R6HP) Alkaline NiMH rechargeable cells may be used. Battery life: 2200 insulation tests with duty cycle of 5 sec ON /55 sec OFF @ 1000 V into 1 M?
Dimensions
Instrument 220 x 92 x 50 mm (8.66 in. x 3.63 in. x 1.97 in.)
Instrument and case 456 x 178 x 89 mm (18 in. x 7 in. x 3.5 in.)
Weight
Instrument only 590 gms (20.73 oz.), 775 gms (27.22 oz.) with boot
Instrument and case 1.75kg (3.86 lb)
Fuse Use only a 500 mA (FF) 1000 V 32 x 6 mm ceramic fuse of highbreaking capacity HBC 50 kA minimum. Glass fuses MUST NOT be fitted.
Safety Protection The instruments meet EN 61010-1 (1995) to 600 V phase to earth, Category IV. Refer to safety warnings supplied.
E.M.C. In accordance with IEC 61326 including amendment No.1
Temperature effects
Temperature coefficient <0.1&Omega per °C up to 1 G&Omega
Environmental
Operating range -10 to +55° C
Operating humidity 90% RH at 40° C max.
Storage temperature range -25 to +70° C
Calibration Temperature +20° C
Maximum altitude 2000 m
Dust and water protection IP54 Protected against dust and splashing water

Key Features

  • CAT IV 600 V rating - provides greater safety when testing at higher voltage levels
  • Adjustable insulation test voltages - provides 250 V to 1000 V or 50 V to 1000 V.
  • Dual digital display readout - allows display of complimentary test information simultaneously (for example: M? plus test voltage or M? plus leakage current)
  • Digital and analog arc display - includes not only the digital readout but also Megger's patented analog arc to replicate the response of a moving coil display
  • Exceptional measurement range from 20 G? to 200 G? - highest insulation test range available on the market, providing a superior range of measurement applications.
  • Choice of 20 mA or 200 mA continuity testing - allows user to select lower continuity range thus increasing battery life considerably
  • Continuity auto-test capability - enables real two-handed operation without the need to press the test button
  • Adjustable continuity limit alarm - allows pass/fail limits to be sent to speed testing
  • Automatically perform PI and DAR tests - user is able to quickly perform two important diagnostic tests. . . Polarization Index (PI) and Dielectric Absorption Ratio (DAR)
  • True RMS voltage measurement - allows accurate voltage measurement on noisy lines
  • Auto ranging voltage measurement - automatically adjusts range from millivolts to 600 V AC or DC, eliminating the need to keep changing ranging
  • Live circuit warning - automatically warns of contact to a live circuit, voltage is displayed and testing is inhibited
  • Auto fuse warning - warns of fuse failure automatically. No need to test the fuse manually.
  • Buzzer select button - enable or disable buzzer as required with resistance also displayed on the screen.
  • Stylish tapered design and center button placement - easy to use with either hand

Specifications (MIT400-EN)

*All quoted accuracies are at +20° C.
Insulation Nominal test voltages 250 V, 500 V, 1000 V
Insulation resistance range 20 G?
Range Full Scale Accuracy 1000 volts ±3% ±2 digits ±0.2% per G? 500 volts ±3% ±2 digits ±0.4% per G? 250 volts ±3% ±2 digits ±0.8% per G?
Analog range 1 G? full scale
Short Circuit Current 2 mA +0% -50%
Terminal voltage -0% +20% ±1 V
Test Current on load 1 mA at min. pass value of insulation specified in BS7671, HD384and IEC364, 2 mA max.
EN61557 Operating range 0.10 M½ to 1.00 G?
Leakage Current 10% ±3 digits
Voltage display 3% ±3 digits ±0.5% of rated voltage
Polarization Index (PI) 10 min/1 minute ratio
Dielectric Absorption Ratio (DAR) 60 sec/30 sec ratio
Notes (1) All ranges measure from 0.00 M½ upwards. (2) Above specifications only apply when high quality silicone leadsare being used.
Continuity
Measurement 0.01 ½ to 99.9 ½ (0 to 100 ½ on analog scale)
Accuracy ±3% ±2 digits (0 to 100 ?)
Open circuit voltage 5 V ±1 V
Test current 200 mA (–0 mA +20 mA) (0.01 ½ to 9.99 ?) 20mA (±1 mA ) (10.0 ½ to 99.9 ?)
Zero offset at probe tips 0.10? typical
Lead resistance zeroing Up to 9.00 ?
Buzzer Variable limit 1?, 2?, 5?,10?, 20?
Resistance
Measurement 0.01 k? to 1000 k? (0 to 1 M? on analog scale)
Accuracy ±3% ±2 digits Open circuit voltage 5 V ±1 V Short circuit current 20 µA ± 5 µA
Voltage range 0 to 600 V d.c. ±2% ±2 digits 10 mV to 600 V TRMS sinusoidal (40 to 400 Hz) ±2% ±2 digits 0 to 1000 V on Analog scale Unspecified input level 0 - 10 mV (40 to 400 Hz) For non-sinusoidal waveforms additional specification apply: ±3% ±2 digits 101 mV to 600 V TRMS and ±8% ±2 digits 10 mV to 100 mV TRMS
Default Voltmeter Operates at >25 V a.c. or d.c. on any range except OFF
Frequency 40 - 450 Hz (40 Hz - 99.9 Hz) ±0.5% ±1 digit (100 Hz to450 Hz)
Result storage
Capacity >1000 test results
Download Bluetooth wireless
Bluetooth Class Class II
Range up to 10 m
Power
Power Supply 5 x 1.5 V cells type IEC LR6 (AA, MN1500, HP7, AM3 R6HP) Alkaline NiMH rechargeable cells may be used. Battery life: 2200 insulation tests with duty cycle of 5 sec ON /55 sec OFF @ 1000 V into 1 M?
Dimensions
Instrument 220 x 92 x 50 mm (8.66 in. x 3.63 in. x 1.97 in.)
Instrument and case 456 x 178 x 89 mm (18 in. x 7 in. x 3.5 in.)
Weight
Instrument only 590 gms (20.73 oz.), 775 gms (27.22 oz.) with boot
Instrument and case 1.75kg (3.86 lb)
Fuse Use only a 500 mA (FF) 1000 V 32 x 6 mm ceramic fuse of highbreaking capacity HBC 50 kA minimum. Glass fuses MUST NOT be fitted.
Safety Protection The instruments meet EN 61010-1 (1995) to 600 V phase to earth, Category IV. Refer to safety warnings supplied.
E.M.C. In accordance with IEC 61326 including amendment No.1
Temperature effects
Temperature coefficient <0.1&Omega per °C up to 1 G&Omega
Environmental
Operating range -10 to +55° C
Operating humidity 90% RH at 40° C max.
Storage temperature range -25 to +70° C
Calibration Temperature +20° C
Maximum altitude 2000 m
Dust and water protection IP54 Protected against dust and splashing water
Shipping & Return
Returns Policy

All returns must be authorized. Items returned prior to authorization will not be accepted. For international customers where applicable, customers must ship any returns to us freight and duty prepaid. Return freight charges for internationsl shippments will be the responsibility of the customer.

Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.

Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.

(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)

Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.

Shipping

We can ship to both US and Canada. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

When you place an order, we will charge a flat rate shipping for your items.

Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.

Not Applicable

Condition: NA

Frequently Asked Questions

  • How do I request a quote?
    To request a quote for pricing on any item found on our site, please click on our "REQUEST A QUOTE" link. Fill out and submit the form, one of our representatives will contact you when the quote is ready.
  • What payment options do I have?
    EquipTestPro accepts a variety of payment options for your convenience. For prepayment, we accept all major credit cards (MasterCard, Visa, Amex, Discover), Purchase Orders, and wire transfers.
  • How do I retturn items?
    All returns must be authorized. Items returned prior to authorization will not be accepted. For international customers where applicable, customers must ship any returns to us freight and duty prepaid. Return freight charges for internationsl shippments will be the responsibility of the customer.

    Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.

    Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.

    (Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)

    Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.

Canada & US Shipping
Rewards Program
Secure Shopping
30-Day Free Returns