Megger MPAC128 Series Acoustic Imaging Camera, 2 to 48 kHz, 1024 x 600
SKU: MPAC128
Availability: 2 to 3 Weeks Megger MPAC128 Offers State-of-the-art acoustic imager visualizes gas leaks and partial discharge with optimal clarity – helping you address issues before they lead to safety incidents, compliance violations, equipment damage, resource wastage, and costly unplanned downtime. Moreover, left undetected, partial discharge (PD) and gas leaks can lead to major failure, explosions, efficiency losses, and downstream impacts
Availability: 2 to 3 Weeks
Megger MPAC128 Offers
State-of-the-art acoustic imager visualizes gas leaks and partial discharge with optimal clarity - helping you address issues before they lead to safety incidents, compliance violations, equipment damage, resource wastage, and costly unplanned downtime. Moreover, left undetected, partial discharge (PD) and gas leaks can lead to major failure, explosions, efficiency losses, and downstream impacts. Identifying PD issues early prevents very costly unplanned outages, equipment failures, safety hazards, and potential regulatory consequences.
With an IP54 rating, it ensures accurate targeting for repairs, preventing safety hazards, production disruptions, and losses, ultimately saving valuable time, energy, and resources. The MPAC128 series also packs impressive reliability with the units ingenious self-check function, meticulously verifying internal components’ integrity and guaranteeing flawless operation of the microphone array, providing unwavering performance day in, day out.
Features
- 128 microphone array
- Detection frequency up to 48 kHz
- Detection ranges up to 393.7' (120 m)
- 8 MP optical camera resolution
- 7” (17.8 cm) screen
- Intelligent analytics
- Ultrasonic monitoring: Modulate signals in the ultrasonic frequency band to an audible frequency band and play them through headphones
- Detects multiple gas types and pressurised gas leaks with ease
- Simple operation with only two parameters to set
- IP54 rating
- Provides leak rate quantification: The screen shows the leak rate and corresponding economic value loss data
- Phase Resolved Partial Discharge (PRPD) for discrimination between different types of partial discharge
- Focus function reduces unwanted noise in noisy environments
- Converts ultrasonic monitoring sounds to audible sounds for pinpointing leaks
- Expandable storage for storing results, images, and videos on site
- Easy update firmware to latest version via the USB-C memory stick or microSD card
- Free Acoustic Analysis software
Applications
- Gas leak detection
- Aid maintenance planning
- Prevention of catastrophic events
- Safety in industrial applications
- Locate partial discharge threats
- Locating and assessing leaks
- Pinpoint the leak
- Locating and identifying PD
- Localization of abnormal noise
Megger MPAC128 Specifications
Specifications
| Acoustic | |
| Microphone Array | 128 channels MEMS microphoneStructural vibration monitoring and localization |
| Effective Test Bandwidth | 2 to 48 kHz |
| Dynamic Range | 0.5 to 12 dB up to 110 dB |
| Test Sound Pressure Level Range | 25.7 to 132.5 dBA |
| Auto Maximum/Minimum dB Gain | User-settable, minimum test bandwidth 1 kHz |
| Number of Digits | 24 bit |
| Sound Image | FOVHorizontal: 62°Vertical: 48°Frame rate: At least 25 FPS |
| Leak Detection Rate | 3.28' (1 m) 7 bar 0.37 ml/seconds32.81' (10 m) 7 bar 0.7 ml/seconds |
| Detect Distances | 0.98 to 393.7' (0.3 to 120 m) |
| General Specifications | |
| Camera | FOVHorizontal: 62°Vertical: 48°Focal length: 3.04 mm fixed focal lengthPixel: 8 million pixel |
| Storage | Internal: About 8 GBExternal: TF memory card, at least 64 GB, expandable to 256 GBData storage format: .jpg (picture), .mp4 (video) and .wav (recording)Video length: 5 minutesDigital export: MicroSD card/USB-C memory stick |
| Display | Resolution: 1024 x 600 (614.400 pixels)Size: 7" (17.8 cm)Touch screen: Capacitive touch screenBrightness: AdjustablePhoto notes: Up to 5 photos notes for referenceSource: Show single or multiple sourcesStandard palettes: Grayscale, ironbow, rainbowPlayback function: View photos, videos anytime, and add notes or tags |
| Software | Report types: Gas/electricity, ISO 50001-compliantAnalysis: Waveform, spectrum, spectrogram, leakage assessment, discharge type discrimination |
| Power | Battery capacity: 1 × 6600 mAH at 7.2 V rechargeable Li-ion battery and 1 × external battery package, continuousBattery life: Approximately 4 hours under full load stateCharger: USB Type-C portOutput: USB-C 5.0 V 3.0 ARated input: 100 to 240 V AC, 50/60 Hz, 1.2 AConsumption: 15 W for battery charge, 29 W for maximum power consumptionEnergy management: User selectable sleep/auto power off modes |
| Environmental Conditions | Operating: -4 to 122°F (-20 to 50°C), 10 to 95% no condensationStorage temperature: -4 to 140°F (-20 to 60°C)Charging temperature: 50 to 113°F (10 to 45°C) |
| Ingress Protection (IP) | IP54 |
| Self-Diagnostic Notification | Array-health test function to identify when microphone array needs attention |
| System | Linux system |
| Certification | CE, FCC, RoHS-compliant, MSDS, CNEXIEC 61010-1IEC 61326-1: Portable Electromagnetic EnvironmentIEC 61326-2-2CISPR 11: Group 1, Class A |
| Dimensions | 10.71 x 6.85 x 1.65" (272 × 174 × 42 mm) |
| Weight | 3.75 lbs (1.7 kg) |
What's included with the Megger MPAC128
- Acoustic Imaging Camera
- Hand Straps
- Shoulder Strap
- Headphone
- Cleaning Tool
- 8 GB MicroSD Card
- USB-A MicroSD Card Reader
- 8 GB USB-C/USB-A Memory Stick
- Hard Carrying Case
- Universal Mains Charger
- USB-C Charge Cable
- Two-Years Warranty
Megger MPAC128 Series Acoustic Imaging Camera, 2 to 48 kHz, 1024 x 600. Get Free Shipping when you buy now from EquipTestPro.com.