Teledyne LeCroy T3DSO1102 Offers

A high speed display technology that provides excellent signal clarity, fidelity and performance, with a low system noise floor. It comes with a minimum vertical input range of 500 uV/div, an innovative digital trigger system with high sensitivity and low jitter, and a waveform capture rate of 400,000 frames/ sec (sequence mode). It also employs a 256-level intensity grading display function and a color temperature display mode.

Features

  • 100 MHz and 200 MHz bandwidths
  • Sample rates up to 1 GS/s.
  • Long Memory – up to 7 Mpts/Ch (14 Mpts interleaved)
  • 7" bright TFT LCD (800 x 480)
  • Serial Bus Trigger and Decode as standard – I2C, SPI, UART, RS232, CAN, LIN allowing users to debug serial buses directly in the oscilloscope
  • Optional MSO – 16 Digital Channels (4 channel models only) which adds mixed signal debugging to the oscilloscope
  • Advanced trigger – edge, slope, pulse width, window, runt, interval, time out (dropout), pattern
  • Waveform Sequence Recorder – record and playback up to 80,000 waveforms. Allows users to replay the changes which have occurred in their waveform history
  • Connectivity – USB for mass storage, printing and PC control, plus LAN for fast data transfer
Functions and Characteristics

Record Length

Up to 14 Mpts (single channel/pair mode), 7 Mpts/CH (two channels/ pair mode). Using hardware-based Zoom technologies and max record length of up to 14 Mpts, users are able to over-sample to capture longer time periods at higher resolution and use the zoom feature to see more details within each signal.

Excellent Something Rate

Two channel series have one 1 GSa/s ADC, four channel series have two 1 GSa/s ADCs. When all channels are enabled, each channel has a maximum sample rate of 500 MSa/s. When a single channel per ADC is active, it has sample rate of 1 GSa/s.

Waveform Capture Rate

With a waveform capture rate of up to 400,000 wfm/s (sequence mode), the oscilloscope can easily capture the unusual or low-probability events.

New generation high speed display technology

  • Waveform capture rate up to 100,000 wfm/s (normal mode), and 400,000 wfm/s sequence mode.
  • Supports 256-level intensity grading and color display modes Record length up to 14 Mpts

Math Functions

FFT, addition, subtraction, multiplication, division, integration, differential, square root which enables speedy extraction of results from waveforms and measurements.

256-Level Intensity Grading and Color Temperature Display

Innovative display technology provides for fast refresh rates. The resulting intensity-graded trace is brighter for events that occur with more frequency and dims when the events occur with less frequency. The color temperature display is similar to the intensity- graded trace function, but the trace occurrence is represented by different colors (color "temperature") as opposed to changes in the intensity of one color. Red colors represents the more frequent events, while blue is used to mark points that occur lest frequently.

History Waveforms (History) Mode and Segmented Acquisition (Sequence)

Playback the latest triggered events using the history function. Segmented memory collection will store trigger events into multiple (Up to 80,000) memory segments. Each segment will store triggered waveforms and timestamp each frame.

Gate and Zoom Measurement

Through Gate and Zoom measurement, the user can specify an arbitrary interval of waveform data analysis and statistics. This helps avoid measurement errors that can be caused by invalid or extraneous data, greatly enhancing the measurements' validity and flexibility.

Multiple Interface Types

USB Host, USB Device (USB-TMC), LAN, Trigger Out thus allowing users to save data for external analysis and screen images for reports.



Teledyne LeCroy T3DSO1102 Specifications

Specifications

Bandwidth100 MHz
Sampling Rate (Max.)Single 1 GSa/s ADC
Channels2+EXT
Memory Depth (Max.)7 Mpts/CH (not interleave mode) 14 Mpts/CH (interleave mode)
Waveform Capture Rate (Max.)100,000 wfm/s (normal mode), 400,000 wfm/s (sequence mode)
Trigger TypeEdge, Slope, Pulse Width, Window, Runt, Interval, Dropout, Pattern, Video
Serial Trigger and Decoder (Standard)IIC, SPI, UART/RS232, CAN, LIN
I/OUSB Host, USB Device, LAN, Pass/Fail, Trigger Out, Sbus
Display7" TFT-LCD (800 x 480)
Electromagnetic Compatibility2004/108/EC Execution Standard EN 61326-1:2006 EN 61000-3-2:2006 + A2:2009, EN 61000-3-3:2008
Safety2006/95/EC Execution Standard EN 61010-1:2010 / EN 61010-2-030:2010
Power SupplyInput Voltage: 100 to 240 VAC, CAT II, Auto selection Frequency: 50/60/400 Hz Power: 25 W Max
Dimensions12.28 x 5.27 x 5.91" (312 x 134 x 150 mm)
Weight5.5 lbs (2.5 kg)


What's included with the Teledyne LeCroy T3DSO1102
  • Oscilloscope
  • Certification
  • Passive Probe
  • USB Cable
  • Power Cord
  • Quick Start
Shipping & Return
Returns Policy

All returns must be authorized. Items returned prior to authorization will not be accepted. For international customers where applicable, customers must ship any returns to us freight and duty prepaid. Return freight charges for internationsl shippments will be the responsibility of the customer.

Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.

Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.

(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)

Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.

Shipping

We can ship to both US and Canada. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

When you place an order, we will charge a flat rate shipping for your items.

Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.

Not Applicable

Condition: NA

Frequently Asked Questions

  • How do I request a quote?
    To request a quote for pricing on any item found on our site, please click on our "REQUEST A QUOTE" link. Fill out and submit the form, one of our representatives will contact you when the quote is ready.
  • What payment options do I have?
    EquipTestPro accepts a variety of payment options for your convenience. For prepayment, we accept all major credit cards (MasterCard, Visa, Amex, Discover), Purchase Orders, and wire transfers.
  • How do I retturn items?
    All returns must be authorized. Items returned prior to authorization will not be accepted. For international customers where applicable, customers must ship any returns to us freight and duty prepaid. Return freight charges for internationsl shippments will be the responsibility of the customer.

    Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.

    Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.

    (Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)

    Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.

Canada & US Shipping
Rewards Program
Secure Shopping
30-Day Free Returns