Teledyne LeCroy T3DSO3054HD OffersThe T3DSO3000HD series employs the latest technology which features a maximum waveform capture rate of up to 200,000 wfm/s in normal mode and 890,000 wfm/s in Sequence mode, 256-level intensity grading display function plus a color temperature display mode. It also employs an innovative digital trigger system with high sensitivity and low jitter
The trigger system supports multiple powerful triggering modes including serial bus triggering. Tools such as History waveform recording, Search and Navigate functions, Mask Test, Bode Plot, and Power Analysis allow for extended waveform records captured, stored, and analyzed. An impressive array of measurement and math capabilities, options for a 50 MHz arbitrary waveform generator, as well as serial decoding are also features of the T3DSO3000HD.
Features
Applications
| Analog Channels | 4 + EXT |
| Bandwidth | 500 MHz |
| Sample Rate (Max.) | 4 GS/s (interleaving), 2 GS/s (non-interleaving) |
| Memory Depth (Max.) | 400 Mpts/ch (single-channel, interleaving), 200 Mpts/ch (dual-channel, interleaving), 100 Mpts/ch (non-interleaving) |
| Waveform Capture Rate (Max.) | 200,000 wfm/s (Normal mode), 890,000 wfm/s (Sequence mode) |
| Vertical Resolution | 12-bit (up to 16-bit in ERES mode) |
| Trigger Type | Edge, Slope, Pulse width, Window, Runt, Interval, Dropout, Pattern, Video, Qualified, Nth edge, Setup/hold, Delay, Serial |
| Serial Trigger & Decode | I²C, SPI, UART, CAN, LIN, CAN FD, FlexRay, I²S, MIL-STD-1553B, SENT, Manchester (decode only), ARINC429 |
| Measurement | 50+ parameters, statistics, histogram, trend, and track supported |
| Math | 4 traces, 4 Mpts FFT, +, -, x, ÷, ∫dt, d/dt, √, Identity, Negation, Absolute, Sign, ex, 10x, ln, lg, Interpolation, MaxHold, MinHold, ERES, Average, Filter (Formula editor supported) |
| Data Analysis | Search, Navigate, History, Mask Test, Digital Voltmeter, Counter, Waveform Histogram, Bode plot, Power Analysis |
| Digital Channel (Optional) | 16-channel, max sample rate 1 GS/s, record length up to 100 Mpts |
| USB AWG Module (Optional) | One channel, 50 MHz, sample rate 125 MHz, wavelength 16 kpts, isolated output |
| I/O | 2 x USB 3.0 Host, USB 2.0 Host, USB 3.0 Device, 10M/100M/1000M LAN, External trigger, Auxiliary output (TRIG OUT, PASS/FAIL) |
| Probe | 4 x 500 MHz passive probes |
| Display | 10.1" (25 cm) TFT-LCD with capacitive touch screen (1024 × 600) |
| Dimensions | 12.49 × 9.29 × 5.87" (317.2 × 236 × 149 mm) including knobs and supporting legs |
| Weight | Net weight: 2.2 lbs (4.1 kg) Gross weight: 12 lbs (5.6 kg) |
All returns must be authorized. Items returned prior to authorization will not be accepted. For international customers where applicable, customers must ship any returns to us freight and duty prepaid. Return freight charges for internationsl shippments will be the responsibility of the customer.
Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.
Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.
(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)
Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.
We can ship to both US and Canada. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.
When you place an order, we will charge a flat rate shipping for your items.
Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.
Not Applicable
| Condition: | NA |
Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.
Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.
(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)
Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.