Winters LIS384 Intrinsically Safe Transmitter, 0 to 20 psi
SKU: LIS384
Availability: 2 to 3 Weeks2 to 3 Weeks Winters LIS384 Offers Approved for intrinsically-safe applications in Class 1/Div. 1 hazardous areas. Features Rugged stainless steel construction with ceramic sensor Available ranges include in/Hg up to 8700 psi Wide range of mechanical and electrical connections 0.5% FSO accuracy Approved for outdoor use Customizable Applications Oil and gas Hazardous areas where an intrinsically safe rating is required Winters LIS
Availability: 2 to 3 Weeks2 to 3 Weeks
Winters LIS384 Offers
Approved for intrinsically-safe applications in Class 1/Div. 1 hazardous areas.
Features
- Rugged stainless steel construction with ceramic sensor
- Available ranges include in/Hg up to 8700 psi
- Wide range of mechanical and electrical connections
- 0.5% FSO accuracy
- Approved for outdoor use
- Customizable
Applications
- Oil and gas
- Hazardous areas where an intrinsically safe rating is required
Winters LIS384 Specifications
| Range | 0 to 20 psi |
| Over-Pressure | 58 psi |
| Burst Pressure | 73 psi |
| Output Signal | Standard 2-wire: 4-20 mA / Vs = 8 to 32 V DC I.S. protection: Vs = 14 to 28 V DC Optional 3-wire: 0 to 20 mA / Vs = 14 to 30 V DC 0 to 10 V / Vs = 14 to 30 V DC |
| Accuracy | ±0.5% FSO IEC 60770 |
| Permissible Load | Current 2-wire: Rmax = [(Vs - Vs min) / 0.02] Ohm Current 3-wire: Rmax = 500 Ohm Voltage 3-wire: Rmin = 10 kOhm |
| Influence Effects | Supply: 0.05% FSO / 10 V Load: 0.05% FSO / kOhm |
| Response Time | ≤10 ms |
| Thermal Error | ≤±0.2% FSO / 10K In compensated range: -13 to 185°F (-25 to 85°C) |
| Permissible Temperatures | Medium: : -40 to 257°F (-40 to 125°C) Electronics environment: -13 to 185°F (-25 to 85°C) Storage: -40 to 212°F (-40 to 100°C) |
| Short-circuit Protection | Permanent |
| Reverse Polarity Protection | No damage. No function |
| Electromagnetic Protection | Emission and immunity according to EN 61326 |
| I.S. Protection | Class 1, Div. 1, Groups A, B, C and D |
| Stability | Vibration: 10 g RMS (25 to 2000 Hz) Shock: 500 g / 1 ms |
| Pollution Degree | 4, electrical equipment for outdoor use |
| Connecting Cables | Cable capacitance: Signal line/shield and signal line/signal line: 160 pF/m Cable inductance: Signal line/shield and signal line/signal line: 1 µH/m |
| Pressure Port/Housing | 316L SS |
| Wetted Parts | Seals: PPN <1450 psi: FKM70. Others available PN >1450 psi: FKM90. Others available Diaphragm: Ceramic AI&sub2;O&sub3; 96% |
| Current Consumption | Current: 25 mA maximum Voltage: 7 mA maximum |
| Operating Life | >100 x 106 cycles |
| Weight | 0.3 lbs (140 g) |