An ergonomic mini-clamp for facilitating work loads to measure low and medium currents from 0.01 to 240 A AC.
Features
Applications
| Current Range | 0.5 to 240 A AC |
| Current Transformation | 1000/1 |
| Output Signal | 1 mA AC / A AC (240 mA for 240 A) |
| Accuracy and Phase Shift | |
| Primary Current | 0.5 to 10 A, 10 A to 40 A, 40 to 100 A, 100 to 240 A |
| % Accuracy of Output Signal | ≤ 3% + 0.5 mA, ≤ 2.5% + 0.5 mA, ≤ 2% + 0.5 mA, ≤ 1% + 0.5 mA |
| Phase Shift | Not specified, ≤5°, ≤3°, ≤2.5° |
| Electrical Specifications | |
| Bandwidth | 40 Hz to 10 kHz |
| Crest Factor | 3 for a current of 200 A RMS |
| Maximum Currents | 200 A continuous for a frequency 3 kHz (limitation proportional to the inverse of one third of frequency beyond) |
| Load Impedance | ≤10 ɷ |
| Operating Voltage | 600 VRMS |
| Common Mode Voltage | 600 V category III and pollution degree 2 |
| Influence of Adjacent Conductor | ≤ 15 mA / A at 50 Hz |
| Influence of Conductor Position in Jaws | ≤ 0.5% of output signal at 50/60 Hz |
| Load Influence 0.2 to 10 ɷ | <0.5 % on measurement < 0.5° on phase |
| Influence of Frequency | <3 % of output signal 40 Hz to 1 kHz |
| Influence of Crest Factor | <4 % of output signal for a crest factor of 3 and current 200 of A RMS |
| Mechanical Specifications | |
| Operating Temperature | 14 to 131°F (-10 to 55°C) |
| Storage Temperature | -40 to 158°F (-40 to 70°C) |
| Influence of temperature | ≤ 0.15% of output signal per 10°K |
| Relative Humidity for Operation | 0 to 85% RH decreasing linearly above 95°F (35°C) |
| Influence of Relative Humidity | <0.2 % of output signal from 10 to 85 % RH |
| Operating Altitude | 0 to 2000 m |
| Maximum Jaw Opening | 20 mm |
| Clamping Capacity | Cable: Ø max 20 mm Busbar: 1 busbar of 20 x 5 mm |
| Casing Protection Rating | IP40 (IEC529) |
| Drop Test | 1m (IEC68-2-32) |
| Shock Resistance | 100 g (IEC68-2-27) |
| Vibration Resistance | 10 / 55/10 Hz, 0.15 mm (IEC68-2-6) |
| Self-Extinguishing Capability | Casing: UL94 V2Jaws: UL94 V0 |
| Output | 1.5 m two-wire lead with double or reinforced insulation terminated by 2 elbowed male safety plugs (4mm) |
| Dimensions | 5.3 x 2.0 x 1.18" (135 x 51 x 30 mm) |
| Weight | 0.39 lbs (180 g) |
| Safety Specifications | |
| Electrical Safety | Instrument with double insulation or reinforced insulation between the primary, the secondary and the grippable part located under the guard as per IEC1010-1 & IEC1010-2-032 600V categoryIII, pollution degree 2 300V category IV, pollution degree 2 |
| Electromagnetic Compatibility | EN50081-1: class B EN50082-2 Electrostatic discharge: IEC1000-4-2 Radiated field: IEC1000-4-3 Fast transients: IEC1000-4-4 Magnetic field at 50/60Hz: IEC1000-4-8 |
All returns must be authorized. Items returned prior to authorization will not be accepted. For international customers where applicable, customers must ship any returns to us freight and duty prepaid. Return freight charges for internationsl shippments will be the responsibility of the customer.
Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.
Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.
(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)
Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.
We can ship to both US and Canada. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.
When you place an order, we will charge a flat rate shipping for your items.
Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.
Not Applicable
| Condition: | NA |
Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.
Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.
(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)
Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.