Features

  • 8ch High-speed simultaneous sampling
  • Includes 500 V measurement with 16-bit A/D converter
  • Equipped with TrueRMS measurement
  • Large built-in RAM (4 M sampling/ch) and built-in flash memory (4 GB)
  • Large easy-to-read 7" LCD
  • High-speed 1 MS/s simultaneous sampling with isolated input
  • Multifunction input with CAT III measurement category: Voltage, temperature, humidity, logic, and pulse measurements can all be taken simultaneously in high speed
  • Supports large built-in RAM (4MS/ch) and built-in flash (4 GB)
  • Convenient data-recording functions
  • Equipped with Ethernet (LAN) and USB interface to communicate with PC
  • PC measurement with standard PC software included (GL980_2000-APS)
  • Advanced software GL-Connection (version 2.0)

Simultaneous Sampling - Sampling interval: 1 µs to 1 min (in steps of 1, 2, 5)

GL980 utilizes simultaneous sampling to eliminate slowdown in sampling rate by using multiple A/D converters in simultaneous sampling method. Eight individual A/D converters in each channel sustains the maximum sampling speed for all eightchannels to measure high speed rapid voltage fluctuation and multi-channel vibration measurement.

External Sampling Function - Maximum input frequency: 100 kHz

Sampling of the logger is performed in sync with an external device using an external signal input. *B-513 Input/Output cable for GL is required

Pulse/Logic

  • Pulse: 4 ch (instant, accumulating RPM)
  • Logic: 4ch
  • *Select either Pulse or Logic. Required input/output cable for GL (B-513 option)

Screw Terminal (size M3.5)

  • Thermocouple: K, J, E, T, R, S, B, N (WRe5-26)
  • Humidity: 1 to 100%
  • *Required humidity sensor (B-530 option)

Applications

  • Measurement of control device
  • Measurement of testing washer and dryer
  • Measurement as an XY recorder
  • Measurement for brake components testing


GRAPHTEC GL980 Specifications

Specifications

Main Unit Specifications
Display (LCD) - Size7-inch TFT color LCD (WVGA: 800 x 480 dots)
Display (LCD) - InformationWaveform in Y-T with digital values, Enlarged waveforms,Digital values and Real-time statistical result values, XY graph
Display (LCD) - LanguageEnglish, French, German, Spanish, Russian, Chinese, Korean, Japanese
Interface to PC - TypeEthernet (10 BASE-T/100 BASE-TX), USB2.0
Interface to PC - FunctionData transfer to PC (up to 1 ms sampling), Control command to GL2000
Interface to PC - Ethernet functionsWeb server function, FTP server function, NTP client function, DHCP client function, Email send function
Interface to PC - USB functionUSB mode (File transfer and deletion from built-in flash and SD on GL2000)
Trigger function - Trigger actionStart or stop capturing data by triggering
Trigger function - Trigger source (Start)Off, Measured signal, Alarm, External, Scheduled time, Scheduled day, Elapsed time
Trigger function - Trigger source (Stop)Off, Measured signal, Alarm, External, Scheduled time, Scheduled day, Elapsed time
Trigger function - CombinationLevel OR, Level AND, Edge OR, Edge AND
Trigger function - Threshold (Analog)High or Low in level mode, Rising or Falling in edge mode, Window-in, Window-out
Trigger function - Threshold (Logic)H or L (4-channel signal pattern)
Trigger function - Threshold (Pulse)High or Rising, Low or Falling, Window-in, Window-out
Trigger function - Repeat actionOff, On (Re-armed automatically)
Trigger function - Trigger hold outHold off repeat action in specified period
Trigger function - ModePrevious start to next start, previous stop to next start
Trigger function - Defection accuracy± 0.5 % of measurement range
Trigger function - Pre-triggerUp to the number of capturing data points (max. 4000000)specified in built-in RAM (only when built-in RAM is used)
Alarm function - Alarm actionDisplays and outputs a signal when alarm is detected
Alarm function - Threshold (Analog input)High, Low, Window-in, Window-out
Alarm function - Threshold (Logic input)H or L (signal in each channel)
Alarm function - Threshold (Pulse input)High or Rising, Low or Falling, Window-in, Window-out
Alarm function - CombinationOR (Source channel can be assigned with OR condition to output port)
Alarm function - Detection cycleLink with analog sampling
Alarm function - Alarm holdingOn or Off
Alarm function - Detection accuracy± 0.5 % of measurement range
Storage device - Built-in RAMFour million samples for each channel
Power consumption (AC adapter in 240 V AC)Approx. 48 V A (66 V A while charging battery) with disabling screen saver
Power consumption (DC drive - 24 V)Approx. 0.6 A (0.9 A while charging battery) with disable screen saver
Power consumption (DC drive - 12 V)Approx. 1.22 A (Cannot charge battery) with disable screen saver
Power consumption (DC drive - 8.5 V)Approx. 1.81 A (Cannot charge battery) with disable screen saver
External dimensions [WxHxD]Approx. 260 x 161 x 83 mm (with the cover)
WeightApprox. 1.7 kg (the cover is attached, AC adapter and battery are not included)
Vibration resistanceCompatible with JIS Vibration test method for automobile Type 1 Class A(Vibration durability test: 5 m/s²)
Analog Unit Specifications
Number of input channels8 channels
Type of input terminalIsolated BNC connector and Screw terminal (M3.5 screw) (*6)
Input methodAll channels isolated unbalanced input, Simultaneous sampling
Sampling speed (interval)1 M Samples/s to 1 Sample/min (1 µs to 1 min) and External (*7)
Sampling interval1, 2, 5, 10, 20, 50, 100, 200, 500 µs
Frequency responseDC to 200 kHz (within +1/-4 dB)
Measurement range - Voltage (DC)20, 50, 100, 200, 500 mV, 1, 2, 5, 10, 20, 50, 100, 200, 500, 1000 V, and 1-5V F.S. * Max. rated safety voltage: ±600 V DC
Measurement range - DC-RMS (DC coupling and rms value meas.)10, 25, 50, 100, 250, 500 mV rms, 1, 2, 5, 10, 25, 50, 100, 250, 500, 1000 V rms F.S. * Max. rated safety voltage: 600 V rms
Measurement range - TemperatureThermocouple: K, J, E, T, R, S, B, N, W (WRe5-26)
Measurement range - Humidity0 to 100 % RH - using the humidity sensor (option B-530)
Filter (Low pass)Off, Line (1.5 Hz), 5, 50, 500 Hz, 50 kHz (at -3dB, -6dB/oct)
A/D converter16-bit (effective resolution: 1/40000 of the measuring full range)
Measurement accuracy - Voltage (DC)± 0.25% of Full Scale
Measurement accuracy - Voltage (RMS)± 1.5% of Full Scale (Sine wave in 20 Hz - 10 kHz)
Measurement accuracy - Temperature (Thermocouple)Type: R/S, B, K, E, T, J, N, W
R.J. CompensationInternal or External
BurnoutDetecting burnout of Thermocouple with menu operation in free-run mode
Input impedance1 M&Ohm; ±5%
Signal source impedanceup to 1 k&Ohm;
Maximum input voltageBetween(+) - (-) terminals: 20 mV to 2 V range: 30 V DC, 5 V to 500 V range: 500 V DCBetween channels (-) - (-) terminals: 60 V P-PBetween channel - GND: 60 V P-P
Isolation ResistanceMin. 50 M&Ohm; (at 500 V DC) with between input and GND
Common-mode rejection ratioMin. 90 dB (50/60 Hz, signal source impedance: max. 300 &Ohm;)
Signal-Noise Ratio (S/N)20 mV range: -40 dB (when input terminals + and - are shorted)Other range: -50 dB (when input terminals + and - are shorted)


What's included with the GRAPHTEC GL980
  • GRAPHTEC GL980 High-Speed and High Voltage Data Logger with 7" color display, 8-channel
Shipping & Return
Returns Policy

All returns must be authorized. Items returned prior to authorization will not be accepted. For international customers where applicable, customers must ship any returns to us freight and duty prepaid. Return freight charges for internationsl shippments will be the responsibility of the customer.

Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.

Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.

(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)

Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.

Shipping

We can ship to both US and Canada. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

When you place an order, we will charge a flat rate shipping for your items.

Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.

Not Applicable

Condition: NA

Frequently Asked Questions

  • How do I request a quote?
    To request a quote for pricing on any item found on our site, please click on our "REQUEST A QUOTE" link. Fill out and submit the form, one of our representatives will contact you when the quote is ready.
  • What payment options do I have?
    EquipTestPro accepts a variety of payment options for your convenience. For prepayment, we accept all major credit cards (MasterCard, Visa, Amex, Discover), Purchase Orders, and wire transfers.
  • How do I retturn items?
    All returns must be authorized. Items returned prior to authorization will not be accepted. For international customers where applicable, customers must ship any returns to us freight and duty prepaid. Return freight charges for internationsl shippments will be the responsibility of the customer.

    Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.

    Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.

    (Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)

    Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.

Canada & US Shipping
Rewards Program
Secure Shopping
30-Day Free Returns