Megger AVO850 OffersThe AVO850 multimeter supports a wide array of measurements, including AC/DC voltage up to 1000 V, AC/DC current up to 10 A, resistance, frequency up to 10 MHz, capacitance up to 10 mF, and temperature. It also features continuity testing with audible and visual indicators, diode testing, and 420 mA process loop measurement with percentage readings, making it versatile for various applications. It also offers Bluetooth connectivity, enabling real-time data sharing with iOS and Android devices through the Megger app.
Features
Applications
AC Voltage | |
500 mV | Resolution: 0.01 mV50/60 Hz: (±0.5% +5)< 1 kHz: ±(1.0% + 5)< 5 kHz: ±(3.0% + 5)<20 kHz*: ±(5.5% + 20)*upper 10 % of range. |
5 V | Resolution: 0.0001 V50/60 Hz: ±(0.5% + 5)< 1 kHz: ±(1.0% + 5)< 5 kHz: ±(3.0% + 5)<20 kHz*: ±(5.5% + 20)*upper 10 % of range. |
50 V | Resolution: 0.001 V50/60 Hz: ±(0.5% + 5)< 1 kHz: ±(1.0% + 5)< 5 kHz: ±(3.0% + 5)<20 kHz*: ±(5.5% + 20)*upper 10 % of range. |
500 V | Resolution: 0.01 V50/60 Hz: ±(1.5% + 10)< 1 kHz: ±(1.5% + 10)< 5 kHz: ±(3.5% + 10)<20 kHz*: unspecified*upper 10 % of range. |
1000 V | Resolution: 0.1 V50/60 Hz: ±(1.5% + 10)< 1 kHz: ±(1.5% + 10)< 5 kHz: unspecified<20 kHz*: unspecified*upper 10 % of range. |
DC Voltage | |
500 mV** When using the relative mode (REL Q) to compensate for offsets. | Resolution: 0.01 mVAccuracy: ±(0.1% + 5 digits) |
5 V | Resolution: 0.0001 VAccuracy: ±(0.05% + 5 digits) |
50 V | Resolution: 0.001 VAccuracy: ±(0.05% + 5 digits) |
500 V | Resolution: 0.01 VAccuracy: ±(0.05% + 5 digits) |
1000 V | Resolution: 0.1 VAccuracy: ±(0.1% + 5 digits) |
(AC+DC) | |
5 V | Resolution: 0.0001 V< 1 kHz: ±(1.2% + 20)< 5 kHz: ±(3.0% + 20) |
50 V | Resolution: 0.001 V< 1 kHz: ±(1.2% + 20)< 5 kHz: ±(3.0% + 20) |
500 V | Resolution: 0.01 V< 1 kHz: ±(1.2% + 20)< 5 kHz: ±(3.0% + 20) |
1000 V | Resolution: 0.1 V< 1 kHz: ±(1.2% + 20)< 5 kHz: ±(3.0% + 20) |
Resistance | |
500 Ω | Resolution: 0.01 ΩAccuracy: ±(0.20% + 10) |
5 kΩ | Resolution: 0.0001 kΩAccuracy: ±(0.20% + 5) |
50 kΩ | Resolution: 0.001 kΩAccuracy: ±(0.20% + 5) |
500 kΩ | Resolution: 0.01 kΩAccuracy: ±(0.50% + 5) |
5 MΩ | Resolution: 0.0001 MΩAccuracy: ±(0.50% + 5) |
50 MΩ | Resolution: 0.001 MΩAccuracy: ±(2.0% + 10) |
Temperature (Type-K) | |
-200 to 1350 °C | Resolution: 0.1 °CAccuracy:±(1.0% reading + 3.0 °C)±(1.0% reading + 5.4 °F)Note: Probe accuracy not included1. Does not include error of the thermocouple probe.2. Accuracy specification assumes ambient temperature stable to ±1 °C.3. Over long use, reading may increase by 2 °C.4. Accuracy for <-50 °C range: ±(3% + 5 °C) |
DC Current | |
500 µA | Resolution: 0.01 µAAccuracy: ±(0.2% + 5) |
5000 µA | Resolution: 0.1 µAAccuracy: ±(0.2% + 5) |
50 mA | Resolution: 0.001 mAAccuracy: ±(0.2% + 5) |
500 mA | Resolution: 0.01 mAAccuracy: ±(0.3% + 8) |
10 A | Resolution: 0.001 AAccuracy: ±(0.5% + 8) |
AC Current | |
500 µA | Resolution: 0.01 µAAccuracy: ±(0.8% + 5) for <1 kHz±(3% + 5) for <5 kHz |
5000 µA | Resolution: 0.1 µAAccuracy:±(0.8% + 5) for <1 kHz ±(3% + 5) for <5 kHz |
50 mA | Resolution: 0.001 mAAccuracy: ±(0.8% + 5) for <1 kHzAccuracy: ±(3% + 5) for <5 kHz |
500 mA | Resolution: 0.01 mAAccuracy:±(0.8% + 5) for <1 kHz ±(3% + 5) for <5 kHz |
10 A | Resolution: 0.001 AAccuracy:±(0.8% + 5) for <1 kHz ±(3% + 5) for <5 kHz |
Note | All AC current ranges are specified from 5% of range to 100% of range |
Capacitance | |
5 nF** With a film capacitor or better, using relative mode (REL) to zero residual | Resolution: 0.001 nFAccuracy: ±(1.5% + 20) |
50 nF | Resolution: 0.01 nFAccuracy: ±(1.5% + 8) |
500 nF | Resolution: 0.1 nFAccuracy: ±(1.0% + 8) |
5 µF | Resolution: 0.001 µFAccuracy: ±(1.5% + 8) |
50 µF | Resolution: 0.01 µFAccuracy: ±(1.0% + 8) |
500 µF | Resolution: 0.1 µFAccuracy: ±(1.5% + 8) |
10 mF | Resolution: 0.01 mFAccuracy: ±(2.5% + 20) |
Electronic Frequency | |
50 Hz | Resolution: 0.001 HzAccuracy: ±(0.01% + 5)Sensitivity: 2 V rms min. at 20 to 80% duty cycle and <100 kHz5 V rms min at 20 to 80% duty cycle and >100 kHz. |
500 Hz | Resolution: 0.01 HzAccuracy: ±(0.01% + 5)Sensitivity: 2 V rms min. at 20 to 80% duty cycle and <100 kHz5 V rms min at 20 to 80% duty cycle and >100 kHz. |
5 kHz | Resolution: 0.0001 kHzAccuracy: ±(0.01% + 5)Sensitivity: 2 V rms min. at 20 to 80% duty cycle and <100 kHz5 V rms min at 20 to 80% duty cycle and >100 kHz. |
50 kHz | Resolution: 0.001 kHzAccuracy: ±(0.01% + 5)Sensitivity: 2 V rms min. at 20 to 80% duty cycle and <100 kHz5 V rms min at 20 to 80% duty cycle and >100 kHz. |
500 kHz | Resolution: 0.01 kHzAccuracy: ±(0.01% + 5)Sensitivity: 2 V rms min. at 20 to 80% duty cycle and <100 kHz5 V rms min at 20 to 80% duty cycle and >100 kHz. |
5 MHz | Resolution: 0.0001 MHzAccuracy: ±(0.01% + 5)Sensitivity: 2 V rms min. at 20 to 80% duty cycle and <100 kHz5 V rms min at 20 to 80% duty cycle and >100 kHz. |
10 MHz | Resolution: 0.001 MHzAccuracy: UnspecifiedSensitivity: 2 V rms min. at 20 to 80% duty cycle and <100 kHz5 V rms min at 20 to 80% duty cycle and >100 kHz. |
Electrical Frequency | |
10.00 Hz to 10 kHz | Resolution: 0.01 Hz - 0.001 kHzAccuracy: ±(0.5% reading)Sensitivity: 2 V rms |
Duty Cycle | |
0.1 to 99.90% | Resolution: 0.01%Accuracy: ±(1.2% reading + 2 digits)Pulse width: 100 µs to 100 msFrequency: 5 Hz to 150 kHz |
General Specifications | |
Maximum voltage | 1000 V (between any terminal and earth ground) |
Fuse protection | F1 - A inputs: 10 A, 1000 V, 30 kAF2 - mA input: 800 mA, 1000 V, 30 kA |
Display | 50 000 count, TFT LCD, 20x per second |
Enclosure | Double molded, IP40 rating |
Environmental Conditions | Operating temperature: 41 to 104°F (5 to 40 °C)Storage temperature: '-4 to 140°F (-20 to 60°C)Operating humidity: Max 80% up to 87°F (31 °C), decreasing linearly to 50% at 104°F (40°C)Storage humidity: 50% at 104 °F (40 °C)Altitude: 2000 m maximumShock (drop test): 6.5' (2 m) |
Battery | Lithium polymer battery (NEDA 1604, 1200 mAh, 7.4 V, 8.88 Wh)Battery life: 300 to 500 charge cycles |
Safety | IEC 61010-1: Pollution Degree 2, IEC 61010-2-033: CAT IV 600 V, CAT III 1000 V |
EMC | IEC 61326-1: Portable Electromagnetic Environment, CISPR 11: Group 1, Class A, IEC 61326-2-2 |
Dimensions | 170 x 79 x 50 mm |
Weight | 376 g (with battery: 416 g) |
All returns must be authorized. Items returned prior to authorization will not be accepted. For international customers where applicable, customers must ship any returns to us freight and duty prepaid. Return freight charges for internationsl shippments will be the responsibility of the customer.
Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.
Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.
(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)
Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.
We can ship to both US and Canada. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.
When you place an order, we will charge a flat rate shipping for your items.
Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.
Not Applicable
Condition: | NA |
Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.
Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.
(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)
Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.