Guaranteed Fitment
Always the correct part
have questions?
Always the correct part
We know our products
Fast & Reliable
Megger AVO850 True RMS AC/DC Data Logging Multimeter, 1000V is available at EquipTestPro.com with fast shipping and great prices.
The AVO850 multimeter supports a wide array of measurements, including AC/DC voltage up to 1000 V, AC/DC current up to 10 A, resistance, frequency up to 10 MHz, capacitance up to 10 mF, and temperature. It also features continuity testing with audible and visual indicators, diode testing, and 420 mA process loop measurement with percentage readings, making it versatile for various applications. It also offers Bluetooth connectivity, enabling real-time data sharing with iOS and Android devices through the Megger app.
Features
Applications
| AC Voltage | |
| 500 mV | Resolution: 0.01 mV50/60 Hz: (±0.5% +5)< 1 kHz: ±(1.0% + 5)< 5 kHz: ±(3.0% + 5)<20 kHz*: ±(5.5% + 20)*upper 10 % of range. |
| 5 V | Resolution: 0.0001 V50/60 Hz: ±(0.5% + 5)< 1 kHz: ±(1.0% + 5)< 5 kHz: ±(3.0% + 5)<20 kHz*: ±(5.5% + 20)*upper 10 % of range. |
| 50 V | Resolution: 0.001 V50/60 Hz: ±(0.5% + 5)< 1 kHz: ±(1.0% + 5)< 5 kHz: ±(3.0% + 5)<20 kHz*: ±(5.5% + 20)*upper 10 % of range. |
| 500 V | Resolution: 0.01 V50/60 Hz: ±(1.5% + 10)< 1 kHz: ±(1.5% + 10)< 5 kHz: ±(3.5% + 10)<20 kHz*: unspecified*upper 10 % of range. |
| 1000 V | Resolution: 0.1 V50/60 Hz: ±(1.5% + 10)< 1 kHz: ±(1.5% + 10)< 5 kHz: unspecified<20 kHz*: unspecified*upper 10 % of range. |
| DC Voltage | |
| 500 mV** When using the relative mode (REL Q) to compensate for offsets. | Resolution: 0.01 mVAccuracy: ±(0.1% + 5 digits) |
| 5 V | Resolution: 0.0001 VAccuracy: ±(0.05% + 5 digits) |
| 50 V | Resolution: 0.001 VAccuracy: ±(0.05% + 5 digits) |
| 500 V | Resolution: 0.01 VAccuracy: ±(0.05% + 5 digits) |
| 1000 V | Resolution: 0.1 VAccuracy: ±(0.1% + 5 digits) |
| (AC+DC) | |
| 5 V | Resolution: 0.0001 V< 1 kHz: ±(1.2% + 20)< 5 kHz: ±(3.0% + 20) |
| 50 V | Resolution: 0.001 V< 1 kHz: ±(1.2% + 20)< 5 kHz: ±(3.0% + 20) |
| 500 V | Resolution: 0.01 V< 1 kHz: ±(1.2% + 20)< 5 kHz: ±(3.0% + 20) |
| 1000 V | Resolution: 0.1 V< 1 kHz: ±(1.2% + 20)< 5 kHz: ±(3.0% + 20) |
| Resistance | |
| 500 Ω | Resolution: 0.01 ΩAccuracy: ±(0.20% + 10) |
| 5 kΩ | Resolution: 0.0001 kΩAccuracy: ±(0.20% + 5) |
| 50 kΩ | Resolution: 0.001 kΩAccuracy: ±(0.20% + 5) |
| 500 kΩ | Resolution: 0.01 kΩAccuracy: ±(0.50% + 5) |
| 5 MΩ | Resolution: 0.0001 MΩAccuracy: ±(0.50% + 5) |
| 50 MΩ | Resolution: 0.001 MΩAccuracy: ±(2.0% + 10) |
| Temperature (Type-K) | |
| -200 to 1350 °C | Resolution: 0.1 °CAccuracy:±(1.0% reading + 3.0 °C)±(1.0% reading + 5.4 °F)Note: Probe accuracy not included1. Does not include error of the thermocouple probe.2. Accuracy specification assumes ambient temperature stable to ±1 °C.3. Over long use, reading may increase by 2 °C.4. Accuracy for <-50 °C range: ±(3% + 5 °C) |
| DC Current | |
| 500 µA | Resolution: 0.01 µAAccuracy: ±(0.2% + 5) |
| 5000 µA | Resolution: 0.1 µAAccuracy: ±(0.2% + 5) |
| 50 mA | Resolution: 0.001 mAAccuracy: ±(0.2% + 5) |
| 500 mA | Resolution: 0.01 mAAccuracy: ±(0.3% + 8) |
| 10 A | Resolution: 0.001 AAccuracy: ±(0.5% + 8) |
| AC Current | |
| 500 µA | Resolution: 0.01 µAAccuracy: ±(0.8% + 5) for <1 kHz±(3% + 5) for <5 kHz |
| 5000 µA | Resolution: 0.1 µAAccuracy:±(0.8% + 5) for <1 kHz ±(3% + 5) for <5 kHz |
| 50 mA | Resolution: 0.001 mAAccuracy: ±(0.8% + 5) for <1 kHzAccuracy: ±(3% + 5) for <5 kHz |
| 500 mA | Resolution: 0.01 mAAccuracy:±(0.8% + 5) for <1 kHz ±(3% + 5) for <5 kHz |
| 10 A | Resolution: 0.001 AAccuracy:±(0.8% + 5) for <1 kHz ±(3% + 5) for <5 kHz |
| Note | All AC current ranges are specified from 5% of range to 100% of range |
| Capacitance | |
| 5 nF** With a film capacitor or better, using relative mode (REL) to zero residual | Resolution: 0.001 nFAccuracy: ±(1.5% + 20) |
| 50 nF | Resolution: 0.01 nFAccuracy: ±(1.5% + 8) |
| 500 nF | Resolution: 0.1 nFAccuracy: ±(1.0% + 8) |
| 5 µF | Resolution: 0.001 µFAccuracy: ±(1.5% + 8) |
| 50 µF | Resolution: 0.01 µFAccuracy: ±(1.0% + 8) |
| 500 µF | Resolution: 0.1 µFAccuracy: ±(1.5% + 8) |
| 10 mF | Resolution: 0.01 mFAccuracy: ±(2.5% + 20) |
| Electronic Frequency | |
| 50 Hz | Resolution: 0.001 HzAccuracy: ±(0.01% + 5)Sensitivity: 2 V rms min. at 20 to 80% duty cycle and <100 kHz5 V rms min at 20 to 80% duty cycle and >100 kHz. |
| 500 Hz | Resolution: 0.01 HzAccuracy: ±(0.01% + 5)Sensitivity: 2 V rms min. at 20 to 80% duty cycle and <100 kHz5 V rms min at 20 to 80% duty cycle and >100 kHz. |
| 5 kHz | Resolution: 0.0001 kHzAccuracy: ±(0.01% + 5)Sensitivity: 2 V rms min. at 20 to 80% duty cycle and <100 kHz5 V rms min at 20 to 80% duty cycle and >100 kHz. |
| 50 kHz | Resolution: 0.001 kHzAccuracy: ±(0.01% + 5)Sensitivity: 2 V rms min. at 20 to 80% duty cycle and <100 kHz5 V rms min at 20 to 80% duty cycle and >100 kHz. |
| 500 kHz | Resolution: 0.01 kHzAccuracy: ±(0.01% + 5)Sensitivity: 2 V rms min. at 20 to 80% duty cycle and <100 kHz5 V rms min at 20 to 80% duty cycle and >100 kHz. |
| 5 MHz | Resolution: 0.0001 MHzAccuracy: ±(0.01% + 5)Sensitivity: 2 V rms min. at 20 to 80% duty cycle and <100 kHz5 V rms min at 20 to 80% duty cycle and >100 kHz. |
| 10 MHz | Resolution: 0.001 MHzAccuracy: UnspecifiedSensitivity: 2 V rms min. at 20 to 80% duty cycle and <100 kHz5 V rms min at 20 to 80% duty cycle and >100 kHz. |
| Electrical Frequency | |
| 10.00 Hz to 10 kHz | Resolution: 0.01 Hz - 0.001 kHzAccuracy: ±(0.5% reading)Sensitivity: 2 V rms |
| Duty Cycle | |
| 0.1 to 99.90% | Resolution: 0.01%Accuracy: ±(1.2% reading + 2 digits)Pulse width: 100 µs to 100 msFrequency: 5 Hz to 150 kHz |
| General Specifications | |
| Maximum voltage | 1000 V (between any terminal and earth ground) |
| Fuse protection | F1 - A inputs: 10 A, 1000 V, 30 kAF2 - mA input: 800 mA, 1000 V, 30 kA |
| Display | 50 000 count, TFT LCD, 20x per second |
| Enclosure | Double molded, IP40 rating |
| Environmental Conditions | Operating temperature: 41 to 104°F (5 to 40 °C)Storage temperature: '-4 to 140°F (-20 to 60°C)Operating humidity: Max 80% up to 87°F (31 °C), decreasing linearly to 50% at 104°F (40°C)Storage humidity: 50% at 104 °F (40 °C)Altitude: 2000 m maximumShock (drop test): 6.5' (2 m) |
| Battery | Lithium polymer battery (NEDA 1604, 1200 mAh, 7.4 V, 8.88 Wh)Battery life: 300 to 500 charge cycles |
| Safety | IEC 61010-1: Pollution Degree 2, IEC 61010-2-033: CAT IV 600 V, CAT III 1000 V |
| EMC | IEC 61326-1: Portable Electromagnetic Environment, CISPR 11: Group 1, Class A, IEC 61326-2-2 |
| Dimensions | 170 x 79 x 50 mm |
| Weight | 376 g (with battery: 416 g) |
Shop EquipTestPro.com for the best deals on Megger AVO850 True RMS AC/DC Data Logging Multimeter, 1000V. Fast shipping, competitive pricing, and expert support. Visit equiptestpro.com today!
Everything you need to know about orders, cancellations, refunds, and delivery.
EquipTestPro ships to both Canada and the United States. We are pleased to serve customers across North America with reliable, trackable delivery options.
When you place an order, a flat-rate shipping charge will be applied at checkout based on your order. The applicable rate will be clearly displayed before you complete your purchase.
Flat-rate shipping is calculated to reflect the cost of reliable, insured delivery. The rate shown at checkout is final — no hidden surcharges will be added after your order is placed.
For certain items, shipping costs are calculated based on the weight of the product. The weight of any weight-based item is listed on its product detail page.
For example, an item weighing 3.2 lbs will be rated at 4 lbs for shipping calculation purposes. This policy is standard practice across all major carriers we work with.
Some products sold on EquipTestPro are subject to shipping restrictions due to regulatory, carrier, or safety requirements. These include but may not be limited to:
Where restrictions apply, this will be clearly noted on the product listing. If you have questions about a specific product's shipping eligibility to your location, please contact us before placing your order.
Orders are processed on business days (Monday through Friday, excluding statutory holidays). Orders placed after business hours or on weekends will begin processing the following business day.
You are entitled to cancel your Order within 30 days of receipt without providing a reason, subject to the processing fee structure described below.
The cancellation deadline is 30 days from the date on which you received the Goods, or on which a third party appointed by you (other than the carrier) takes possession of the delivered product.
To exercise your cancellation right, notify us with a clear written statement by:
The following fee structure applies to all cancellations. Please review carefully before requesting a cancellation.
A processing fee of 10% of the total order value will be withheld from your refund to cover payment processing, handling, and administrative costs.
If we cancel your order due to item unavailability, no processing fee will be withheld. You receive a full refund of the amount paid.
Refunds will be issued using the same payment method as the original purchase. No additional fees beyond those described above will be applied.
To be eligible for a return, all of the following conditions must be met:
We reserve the right to refuse returns of any merchandise that does not meet the above conditions, at our sole discretion.
The following items are not eligible for return under any circumstances:
You are responsible for the cost and risk of returning Goods to us. Before sending any items, please contact us at info@equiptestpro.com to obtain the return shipping address.
You should expect to receive your refund within four (4) weeks of delivering your return package to the shipper. In many cases, refunds are processed sooner. The timeline breaks down as follows:
We will process refunds no later than 14 days from the day we receive the returned Goods, using the same payment method as your original purchase.
If the Goods were marked as a gift at the time of purchase and shipped directly to you, a gift credit equal to the return value (less any applicable processing fee) will be issued. Once the returned product is received and inspected, a gift certificate will be mailed to you.
If the Goods were not marked as a gift at purchase, or if the gift giver had the order shipped to themselves first, the refund will be issued to the original purchaser.
Reach out to our support team for assistance with any order or return.
Not Applicable
| Condition: | NA |
Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.
Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.
(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)
Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.