null
close
close
click to zoom in
  • Guaranteed Fitment

    Always the correct part

  • In-House Experts

    We know our products

  • Added Value

    Fast & Reliable

  • US & Canada Delivery

Megger EVCC300 Electric Vehicle Charger Checker

No reviews yet Write a Review
$1,999.57
SKU:
EVCC300
Condition:
New
Availability:
In Stock
5 customers are viewing this product

Megger EVCC300 Electric Vehicle Charger Checker

$1,999.57

Megger EVCC300

Capable of checking mode 2 and single-phase mode 3 (level 1 and two-phase level 2) chargers, this EV charger checker can perform four EV charger safety and operation checks. In addition, this checker increases ground/earth leakage current until the protective device trips to ensure it trips at the correct leakage current level. If the leakage current that trips the device is too low, it will indicate there is an issue with the device or that there is already a high level of leakage present.

Features

  • Checks mode 2 and single-phase mode 3 (level 1 and two-phase level 2) chargers
  • Checks chargers with SAE J1772 Type 1 and Type 2 connectors
  • Performs four EV charger safety checks
  • Performs four EV charger operation checks
  • Checks to see if nuisance tripping or RCD/GFCI is likely to occur
  • Reads control pilot state response from EV charger to IEC61852-1

Four important safety checks

  • PE touchpad to check ground connection and hazardous voltages
  • PE resistance (RPE) test to check any exposed metal work is properly grounded/earthed
  • Touch voltage test to ensure the charger ground/earth does not rise to a hazardous level when charger output is on
  • RCD/GFCI protection check by timing the device tripping speed. This test causes a calibrated ground/earth leakage current appropriate to the trip rating of the device to flow and time how long it takes for the device to break the supply. If an RCD/GFCI was to take too long to trip it would not protect the charger user from electrocution, so it is an important safety check

Nuisance charger supply tripping check

This test will help determine whether the EV charger user is likely to experience nuisance tripping of the RCD or GFCI. This charger checker slowly increases ground/earth leakage current until the protective device trips to ensure it trips at the correct leakage current level. If the leakage current that trips the device is too low it will indicate either an issue with the device or there is already a high level of leakage present.

Four key EV charger operation checks

  • Proximity detection operation check: Checks that proximity is detected and also whether, when testing a type 1 connection, that latching detection has worked correctly
  • Control pilot operation check: Not only can this charger checker set CP states to operate the EV charger, but it can also read the response state of the charger. The codes A, B, C, D, E, and F can be set and the response of the charger is displayed on the instrument's color display. The charger PC state is displayed together with the charger indicated maximum charge current, all to IEC61851-1 requirements
  • Control pilot signal check: Measures the CP signal voltage, frequency, and duty cycle, and repeated measurements will highlight instability in the signal
  • EV charger output check: Measures the output voltage and frequency of the EV charger when charging is in progress, and when appropriate it also checks for correct L - N supply polarity

Applications

  • Safety and operation checks on mode 2 and single-phase mode 3 charge points (level 1 and two-phase level 2 in USA)
  • Connecting to SAE J1772 type 1 and type 2 charger connectors
  • Checking charger following installation and repair before hand over to customer
  • Checking charger as part of a regular maintenance schedule
  • Checking charger following manufacturing as part of a QA inspection
  • Fault checking when customer reports charger issues to car dealership/service center

Megger EVCC300 Specifications

EVSE Standard: IEC 61851-1:2017
Supply options (set in settings)
1. 230 V single-phase
2. 120 V single-phase
3. 208 V two-phase
4. 240 V two-phase
Supply Measurement Voltage
Range: 5 to 300 V
Resolution: 1 V
Accuracy: ±5% ±2 digits
Measurement: L to N, L to PE and N to PE
Reverse polarity indication: L to N, for single-phase option only

Frequency
Range: 45 to 65 Hz
Resolution: 1 Hz
Accuracy: ±1 digit
EVSE Interface (EV Charger Function) Tests 1. Proximity detection (PP) states
Read only
No proximity
Proximity detected, unlatched
Proximity detected, latched

2. Control pilot (CP)
Set and read states: State A (disconnected), State B (connected), State C (charging), State D (charging without ventilation), State E (CP short to PE)
Read only state: State F - EVSE charger fault condition
Maximum voltage: ±14 V
Frequency: 940 to 1040 Hz
Duty cycle: 8 to 97%
Maximum charging current indication according to IEC 61851-1:2017, tables A.7 and A.8
Resistance of Earth Protective Conductor (RPE) Test current: 200 mA
Range: 0 to 10 ?
Resolution: 0.01 ?
Accuracy: ±5% ±2 digits
RCD/GFCI Tests Trip time accuracy: ±1% ±1 ms
Trip current accuracy: ±3% (apply to all RCD/GFCI tests)
Personal Protection Tests
230 V Single-Phase
1. RCD 30 mA AC test
Current: 31.5 mA AC (5% above nominal trip current)
Accuracy: ±1.0 mA
Maximum test time: 300 ms
Polarity selection: 0 and 180° of an input sine wave

2. RCD 6 mA DC test
Ramp: Up at rate of 6 mA in 2.5 seconds, then held at 6 mA DC
Accuracy: ±0.5 mA
Ramp polarity: Positive and negative ramp
Maximum test time: 12.5 seconds
Polarity selection: 0 and 180° of an input sine wave
Personal Protection Tests
120 V Single-Phase/240 V Two-Phase
1. GFCI/CCID 5 mA AC test
Current: 6 mA AC
Accuracy: ±0.5 mA
Maximum test time: 5.59 seconds
Polarity selection: 0 and 180° of an input sine wave

2. GFCI/CCID 20 mA AC test
Current: 21 mA AC (5% above nominal trip current)
Accuracy: ±0.5 mA
Maximum test time: 5.59 seconds
Polarity selection: 0 and 180° of an input sine wave
Nuisance Tripping Tests
230 V Single-Phase
1. RCD AC Ramp test
Current: AC current ramp up to 30 mA in 2 mA steps
Accuracy: ±0.5 mA
Step time: 300 ms
Maximum test time: 4.5 seconds

2. RCD DC Ramp test
Test current ramp up at rate of 6 mA in 2.5 seconds, then held at 3 mA DC
Maximum test time: 11.25 seconds
Nuisance Tripping Tests
120 V Single-Phase/240 V Two-Phase
1. GFCI/CCID 5 mA AC test
Current: AC current ramp up to 6 mA in 0.5 mA steps
Accuracy: ±0.5 mA
Step time: 100 ms
Maximum test time: 1.2 seconds

2. GFCI/CCID 20 mA AC test
Current: AC current ramp up to 20 mA in 1 mA steps
Accuracy: ±0.5 mA
Step time: 100 ms
Maximum test time: 2 seconds
Touch Tests Voltage: Test current typically ? of RCD nominal test current
Contact pad: Dangerous voltage indication at PE conductor
Connections Main test: Type 2 male
RPE test return: 0.157" (4 mm) shrouded socket on base of handle
Languages English, French, German and Spanish
Environment Conditions Temperature: Operating: 32 to 104°F (0 to 40°C); Storage: 14 to 158°F (-10 to 70°C)
Operating humidity: 90% RH at 104°F (40°C) maximum
Maximum altitude: 6561.68' (2000 m)
Dust and moisture ingress: IP40 to IEC60529 in use
Safety Standards: IEC 61010-1:2010
EVSE standard: IEC 61851-1:2017
Category: CAT II 300 V
Power Supply 4 x AA cells
Dimensions 9.45 x 3.38 x 7.09" (24 x 8.6 x 18 cm)
Weight 1.28 lbs (583 g) without batteries

Megger EVCC300 Specifications

EVSE Standard: IEC 61851-1:2017
Supply options (set in settings)
1. 230 V single-phase
2. 120 V single-phase
3. 208 V two-phase
4. 240 V two-phase
Supply Measurement Voltage
Range: 5 to 300 V
Resolution: 1 V
Accuracy: ±5% ±2 digits
Measurement: L to N, L to PE and N to PE
Reverse polarity indication: L to N, for single-phase option only

Frequency
Range: 45 to 65 Hz
Resolution: 1 Hz
Accuracy: ±1 digit
EVSE Interface (EV Charger Function) Tests 1. Proximity detection (PP) states
Read only
No proximity
Proximity detected, unlatched
Proximity detected, latched

2. Control pilot (CP)
Set and read states: State A (disconnected), State B (connected), State C (charging), State D (charging without ventilation), State E (CP short to PE)
Read only state: State F - EVSE charger fault condition
Maximum voltage: ±14 V
Frequency: 940 to 1040 Hz
Duty cycle: 8 to 97%
Maximum charging current indication according to IEC 61851-1:2017, tables A.7 and A.8
Resistance of Earth Protective Conductor (RPE) Test current: 200 mA
Range: 0 to 10 ?
Resolution: 0.01 ?
Accuracy: ±5% ±2 digits
RCD/GFCI Tests Trip time accuracy: ±1% ±1 ms
Trip current accuracy: ±3% (apply to all RCD/GFCI tests)
Personal Protection Tests
230 V Single-Phase
1. RCD 30 mA AC test
Current: 31.5 mA AC (5% above nominal trip current)
Accuracy: ±1.0 mA
Maximum test time: 300 ms
Polarity selection: 0 and 180° of an input sine wave

2. RCD 6 mA DC test
Ramp: Up at rate of 6 mA in 2.5 seconds, then held at 6 mA DC
Accuracy: ±0.5 mA
Ramp polarity: Positive and negative ramp
Maximum test time: 12.5 seconds
Polarity selection: 0 and 180° of an input sine wave
Personal Protection Tests
120 V Single-Phase/240 V Two-Phase
1. GFCI/CCID 5 mA AC test
Current: 6 mA AC
Accuracy: ±0.5 mA
Maximum test time: 5.59 seconds
Polarity selection: 0 and 180° of an input sine wave

2. GFCI/CCID 20 mA AC test
Current: 21 mA AC (5% above nominal trip current)
Accuracy: ±0.5 mA
Maximum test time: 5.59 seconds
Polarity selection: 0 and 180° of an input sine wave
Nuisance Tripping Tests
230 V Single-Phase
1. RCD AC Ramp test
Current: AC current ramp up to 30 mA in 2 mA steps
Accuracy: ±0.5 mA
Step time: 300 ms
Maximum test time: 4.5 seconds

2. RCD DC Ramp test
Test current ramp up at rate of 6 mA in 2.5 seconds, then held at 3 mA DC
Maximum test time: 11.25 seconds
Nuisance Tripping Tests
120 V Single-Phase/240 V Two-Phase
1. GFCI/CCID 5 mA AC test
Current: AC current ramp up to 6 mA in 0.5 mA steps
Accuracy: ±0.5 mA
Step time: 100 ms
Maximum test time: 1.2 seconds

2. GFCI/CCID 20 mA AC test
Current: AC current ramp up to 20 mA in 1 mA steps
Accuracy: ±0.5 mA
Step time: 100 ms
Maximum test time: 2 seconds
Touch Tests Voltage: Test current typically ? of RCD nominal test current
Contact pad: Dangerous voltage indication at PE conductor
Connections Main test: Type 2 male
RPE test return: 0.157" (4 mm) shrouded socket on base of handle
Languages English, French, German and Spanish
Environment Conditions Temperature: Operating: 32 to 104°F (0 to 40°C); Storage: 14 to 158°F (-10 to 70°C)
Operating humidity: 90% RH at 104°F (40°C) maximum
Maximum altitude: 6561.68' (2000 m)
Dust and moisture ingress: IP40 to IEC60529 in use
Safety Standards: IEC 61010-1:2010
EVSE standard: IEC 61851-1:2017
Category: CAT II 300 V
Power Supply 4 x AA cells
Dimensions 9.45 x 3.38 x 7.09" (24 x 8.6 x 18 cm)
Weight 1.28 lbs (583 g) without batteries

Megger EVCC300 Specifications

EVSE Standard: IEC 61851-1:2017
Supply options (set in settings)
1. 230 V single-phase
2. 120 V single-phase
3. 208 V two-phase
4. 240 V two-phase
Supply Measurement Voltage
Range: 5 to 300 V
Resolution: 1 V
Accuracy: ±5% ±2 digits
Measurement: L to N, L to PE and N to PE
Reverse polarity indication: L to N, for single-phase option only

Frequency
Range: 45 to 65 Hz
Resolution: 1 Hz
Accuracy: ±1 digit
EVSE Interface (EV Charger Function) Tests 1. Proximity detection (PP) states
Read only
No proximity
Proximity detected, unlatched
Proximity detected, latched

2. Control pilot (CP)
Set and read states: State A (disconnected), State B (connected), State C (charging), State D (charging without ventilation), State E (CP short to PE)
Read only state: State F - EVSE charger fault condition
Maximum voltage: ±14 V
Frequency: 940 to 1040 Hz
Duty cycle: 8 to 97%
Maximum charging current indication according to IEC 61851-1:2017, tables A.7 and A.8
Resistance of Earth Protective Conductor (RPE) Test current: 200 mA
Range: 0 to 10 ?
Resolution: 0.01 ?
Accuracy: ±5% ±2 digits
RCD/GFCI Tests Trip time accuracy: ±1% ±1 ms
Trip current accuracy: ±3% (apply to all RCD/GFCI tests)
Personal Protection Tests
230 V Single-Phase
1. RCD 30 mA AC test
Current: 31.5 mA AC (5% above nominal trip current)
Accuracy: ±1.0 mA
Maximum test time: 300 ms
Polarity selection: 0 and 180° of an input sine wave

2. RCD 6 mA DC test
Ramp: Up at rate of 6 mA in 2.5 seconds, then held at 6 mA DC
Accuracy: ±0.5 mA
Ramp polarity: Positive and negative ramp
Maximum test time: 12.5 seconds
Polarity selection: 0 and 180° of an input sine wave
Personal Protection Tests
120 V Single-Phase/240 V Two-Phase
1. GFCI/CCID 5 mA AC test
Current: 6 mA AC
Accuracy: ±0.5 mA
Maximum test time: 5.59 seconds
Polarity selection: 0 and 180° of an input sine wave

2. GFCI/CCID 20 mA AC test
Current: 21 mA AC (5% above nominal trip current)
Accuracy: ±0.5 mA
Maximum test time: 5.59 seconds
Polarity selection: 0 and 180° of an input sine wave
Nuisance Tripping Tests
230 V Single-Phase
1. RCD AC Ramp test
Current: AC current ramp up to 30 mA in 2 mA steps
Accuracy: ±0.5 mA
Step time: 300 ms
Maximum test time: 4.5 seconds

2. RCD DC Ramp test
Test current ramp up at rate of 6 mA in 2.5 seconds, then held at 3 mA DC
Maximum test time: 11.25 seconds
Nuisance Tripping Tests
120 V Single-Phase/240 V Two-Phase
1. GFCI/CCID 5 mA AC test
Current: AC current ramp up to 6 mA in 0.5 mA steps
Accuracy: ±0.5 mA
Step time: 100 ms
Maximum test time: 1.2 seconds

2. GFCI/CCID 20 mA AC test
Current: AC current ramp up to 20 mA in 1 mA steps
Accuracy: ±0.5 mA
Step time: 100 ms
Maximum test time: 2 seconds
Touch Tests Voltage: Test current typically ? of RCD nominal test current
Contact pad: Dangerous voltage indication at PE conductor
Connections Main test: Type 2 male
RPE test return: 0.157" (4 mm) shrouded socket on base of handle
Languages English, French, German and Spanish
Environment Conditions Temperature: Operating: 32 to 104°F (0 to 40°C); Storage: 14 to 158°F (-10 to 70°C)
Operating humidity: 90% RH at 104°F (40°C) maximum
Maximum altitude: 6561.68' (2000 m)
Dust and moisture ingress: IP40 to IEC60529 in use
Safety Standards: IEC 61010-1:2010
EVSE standard: IEC 61851-1:2017
Category: CAT II 300 V
Power Supply 4 x AA cells
Dimensions 9.45 x 3.38 x 7.09" (24 x 8.6 x 18 cm)
Weight 1.28 lbs (583 g) without batteries
Shipping & Return
Returns Policy

All returns must be authorized. Items returned prior to authorization will not be accepted. For international customers where applicable, customers must ship any returns to us freight and duty prepaid. Return freight charges for internationsl shippments will be the responsibility of the customer.

Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.

Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.

(Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)

Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.

Shipping

We can ship to both US and Canada. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

When you place an order, we will charge a flat rate shipping for your items.

Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.

Not Applicable

Condition: NA

Frequently Asked Questions

  • How do I request a quote?
    To request a quote for pricing on any item found on our site, please click on our "REQUEST A QUOTE" link. Fill out and submit the form, one of our representatives will contact you when the quote is ready.
  • What payment options do I have?
    EquipTestPro accepts a variety of payment options for your convenience. For prepayment, we accept all major credit cards (MasterCard, Visa, Amex, Discover), Purchase Orders, and wire transfers.
  • How do I retturn items?
    All returns must be authorized. Items returned prior to authorization will not be accepted. For international customers where applicable, customers must ship any returns to us freight and duty prepaid. Return freight charges for internationsl shippments will be the responsibility of the customer.

    Defective new equipment may be returned for warrantyrepair/exchange to us within (5) days of the shipment receipt date. After five (5) days, returns will be handled by direct contact and in accordance with the warranty terms of the item's manufacturer. Items that have malfunctioned due to mishandling, electrical overload, etc., will be subject to repair charge.

    Non defective new equipment will be authorized for return within five (5) days of the shipment receipt date if the equipment is still in new, re-sellable condition with the original manual(s), accessories, packing material and carton. We reserve the right to reject returnsin which there is no original packaging, missing accessories, damage or visible signs of usage of the item. A restocking fee of up to 25% of purchase price may apply. Special orders and dangerous goods are non-returnable.

    (Do not write anytingon the manufacturer's original package or use as a shipping carton. Include all accessories, manuals and warranties.)

    Please, include a copy of the packing list or invoice with a reason for the return. Your return authorization number is valid for thirty (30) days.

Canada & US Shipping
Rewards Program
Secure Shopping
30-Day Free Returns